AIR FUEL RATIO SENSOR(for Sensor 2) INSPECTION
PROCEDURE
INSPECT AIR FUEL RATIO SENSOR
-
*a
Component without harness connected
(air fuel ratio sensor)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (HA1B) - 2 (+B)
20°C (68°F)
2 to 6 Ω
1 (HA1B) - 4 (A1B-)
Always
10 kΩ or higher
If the result is not as specified, replace the air fuel ratio sensor.
-