| DTC Code | DTC Name |
|---|---|
| B1507 | Open in Turn Signal Circuit |
| B1508 | Short in Turn Signal / Hazard Flasher Circuit |
DESCRIPTION
These DTCs are stored when the combination meter sub-assembly detects an open in a turn signal light circuit, a short in a turn signal light circuit, or a short in the hazard warning light circuit.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1507 | When IG voltage is 9.5 V or more and the following condition is detected:
|
|
| B1508 | When IG voltage is 9.5 V or more and the following condition is detected:
|
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect the bulbs for this system before performing the following inspection procedure.
PROCEDURE
INSPECT LIGHTS
Inspect the illumination of each turn signal light.
| Result | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
| B |
|
CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) Click here |
| C |
|
CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) Click here |
| D |
|
CHECK HARNESS AND CONNECTOR (OUTER REAR VIEW MIRROR ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) Click here |
| A |
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER SUB-ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the L125 combination meter sub-assembly connector.
Disconnect the 2A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| B |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |
CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the C8*1 or C7*2 front turn signal light connector.
*1: for LH
*2: for RH
Disconnect the 2C instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|||||||||
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| B |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |
CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the R17*1 or S18*2 rear turn signal light connector.
*1: for LH
*2: for RH
Disconnect the 2D instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|||||||||
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| B |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |
CHECK HARNESS AND CONNECTOR (OUTER REAR VIEW MIRROR ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the O12*1 or N12*2 outer rear view mirror assembly connector.
*1: for LH
*2: for RH
Disconnect the 2B instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|||||||||
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Result | ||||||
|---|---|---|---|---|---|---|
|
| A |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| B |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| *a | Component without harness connected (Instrument Panel Junction Block Assembly) |
| OK |
|
REPLACE METER CIRCUIT PLATE Click here |
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |