INFRARED RAY SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONING INFRARED RAYS SENSOR


    1. B005X8D

      Install the air conditioning infrared sensor with the 2 screws and connect the connector.

    2. Install the wire harness to the clamp.

    3. B005VTVC01
      B006AHR Screw
      B006EC9 Connector

      Connect the connector.

    4. Attach the claw and install the 2 screws.

    5. Install the wire harness to the clamp.

  2. INSTALL MAP LIGHT SUB-ASSEMBLY

    Click here

  3. INSPECT AIR CONDITIONING INFRARED RAYS SENSOR


    1. Operate the air conditioning infrared sensor so that the ECU recognizes it.


      1. Turn the power switch on (IG) so that the air conditioning amplifier recognizes the air conditioning infrared sensor.

        Note

        If the sensor is not operated after it is removed, the ECU does not recognize its existence.