STOP AND START SYSTEM(for 3ZR-FAE) Stop and Start Cancel Switch Circuit

DTC Code DTC Name
Stop and Start Cancel Switch Circuit

DESCRIPTION

Stop and start control can be disabled by pressing the stop and start system cancel switch (combination switch assembly). The stop and start system cancel switch (combination switch assembly) is a momentary-type switch that switches between on and off when the switch is pressed. While stop and start control is disabled, the stop and start cancel indicator light is illuminated to inform the driver.

WIRING DIAGRAM

A287084E47

PROCEDURE

  1. READ VALUE USING GTS (CANCEL SWITCH)

    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Cancel Switch.

    5. Read the value when the stop and start system cancel switch (ecorun cancel switch assembly) is pressed.

      Powertrain > Stop and Start > Data List

      Tester Display

      Cancel Switch

      OK

      Tester Display

      Condition

      Normal Condition

      Cancel Switch

      Stop and start system cancel switch (ecorun cancel switch assembly) is pressed

      ON

      Stop and start system cancel switch (ecorun cancel switch assembly) is not pressed

      OFF

    Result

    Proceed to

    OK

    NG

    OK

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

    NG
  2. INSPECT STOP AND START SYSTEM CANCEL SWITCH (COMBINATION SWITCH ASSEMBLY)

    1. Inspect the stop and star system cancel switch (combination switch assembly).

      Click here

    Result

    Proceed to

    OK

    NG

    NG

    REPLACE ENGINE STOP AND START SYSTEM CANCEL SWITCH (COMBINATION SWITCH ASSEMBLY)

    OK
  3. CHECK HARNESS AND CONNECTOR (STOP AND START SYSTEM CANCEL SWITCH (COMBINATION SWITCH ASSEMBLY) - BODY GROUND)

    1. Disconnect the G185 stop and start system cancel switch (combination switch assembly) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      G185-6 (MSW2) - Body ground

      Always

      Below 1 Ω

    Result

    Proceed to

    OK

    NG

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR

    OK
  4. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - STOP AND START SYSTEM CANCEL SWITCH (COMBINATION SWITCH ASSEMBLY))

    1. Disconnect the G87 engine stop and start ECU connector.

    2. Disconnect the G185 stop and start system cancel switch (combination switch assembly) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      G87-5 (ECAN) - G185-5 (ECU)

      Always

      Below 1 Ω

      G87-5 (ECAN) - Body ground

      Always

      10 kΩ or higher

      G185-5 (ECU) - Body ground

      Always

      10 kΩ or higher

    Result

    Proceed to

    OK

    NG

    OK

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR