SLIDE DOOR LOCK INSPECTION


  1. INSPECT POWER SLIDE DOOR LOCK ASSEMBLY RH


    1. B007TRVE03

      Inspect the door closer motor.


      1. Apply battery voltage and check operation of the slide door closer motor.

        Standard
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        Close (Forward)

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Open (Reverse)
    2. B007RJGE03

      Inspect the pawl switch and latch switch


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        Pawl switch
        Tester Connection Condition Specified Condition
        8 - 9
        • Open


        • Half latch


        • Full latch

        10 kΩ or higher
        8 - 9 Unlatched Below 1 Ω
        Latch switch
        Tester Connection Condition Specified Condition
        3 - 4, 4- 8 Open Below 1 Ω
        4 - 8 Half latch Below 1 Ω
        3 - 4, 4- 8 Full latch 10 kΩ or higher
        - Over stroke 10 kΩ or higher
    3. B007QW0E02

      Inspect the initial position switch and handle switch.


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        Tester Connection Condition Specified Condition
        8 - 10
        • Handle switch ON (Handle initial position)


        • Initial position switch OFF (Active lever initial position)

        10 kΩ or higher
        8 - 10
        • Handle switch OFF (As handling)


        • Initial position switch OFF (Active lever initial position)

        10 kΩ or higher
        8 - 10
        • Handle switch ON (Handle initial position)


        • Initial position switch ON (As closer operating)

        Below 1 Ω
        8 - 10
        • Handle switch OFF (As handling)


        • Initial position switch ON (As closer operating)

        10 kΩ or higher
  2. INSPECT POWER SLIDE DOOR LOCK ASSEMBLY LH


    1. B007V45E02

      Inspect the door closer motor.


      1. Apply battery voltage and check operation of the slide door closer motor.

        Standard
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        Close (Forward)

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Open (Reverse)
    2. B007W5IE02

      Inspect the pawl switch and latch switch


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        Pawl switch
        Tester Connection Condition Specified Condition
        8 - 9
        • Open


        • Half latch


        • Full latch

        10 kΩ or higher
        8 - 9 Unlatched Below 1 Ω
        Latch switch
        Tester Connection Condition Specified Condition
        3 - 4, 4- 8 Open Below 1 Ω
        4 - 8 Half latch Below 1 Ω
        3 - 4, 4- 8 Full latch 10 kΩ or higher
        - Over stroke 10 kΩ or higher
    3. B007OSPE02

      Inspect the initial position switch and handle switch.


      1. Measure the resistance when the switch is operated according to the value(s) in the table below.

        Standard resistance
        Tester Connection Condition Specified Condition
        8 - 10
        • Handle switch ON (Handle initial position)


        • Initial position switch OFF (Active lever initial position)

        10 kΩ or higher
        8 - 10
        • Handle switch OFF (As handling)


        • Initial position switch OFF (Active lever initial position)

        10 kΩ or higher
        8 - 10
        • Handle switch ON (Handle initial position)


        • Initial position switch ON (As closer operating)

        Below 1 Ω
        8 - 10
        • Handle switch OFF (As handling)


        • Initial position switch ON (As closer operating)

        10 kΩ or higher