GENERATOR(for 80A Type) INSPECTION
PROCEDURE
INSPECT GENERATOR WITH CLUTCH PULLEY
-
*a
Free
*b
Lock
Hold the center of the generator with clutch pulley, and confirm that the outer ring turns counterclockwise and does not turn clockwise.
OK
The outer ring turns counterclockwise and does not turn clockwise.
If the result is not as specified, replace the generator with clutch pulley.
-
INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
-
*a
Length
Using a vernier caliper, measure the length of the exposed brushes.
Standard Exposed Length
9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum Exposed Length
4.5 mm (0.177 in.)
If the exposed length is less than the minimum, replace the generator brush holder assembly.
-
INSPECT GENERATOR ROTOR ASSEMBLY
-
*a
Slip Ring
Check the generator rotor assembly for an open circuit.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
Slip ring - Slip ring
20°C (68°F)
1.85 to 2.25 Ω
If the result is not as specified, replace the generator rotor assembly.
-
*a
Slip Ring
*b
Rotor
Check the generator rotor assembly for a short to ground.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
Slip ring - Rotor
Always
10 MΩ or higher
If the result is not as specified, replace the generator rotor assembly.
-
Check that the bearing is not rough or worn and that it rotates smoothly.
If the bearing does not rotate smoothly, replace the generator rotor assembly.
-
*a
Diameter
Using a vernier caliper, measure the slip ring diameter.
Standard Diameter
14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum Diameter
14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.
-
Check that the slip rings are not rough or scored.
If rough or scored, replace the generator rotor assembly.
-
INSPECT GENERATOR DRIVE END FRAME BEARING
-
Check that the generator drive end frame bearing is not rough or worn and that it rotates smoothly.
If the bearing does not rotate smoothly, replace the generator drive end frame bearing.
-