GENERATOR REMOVAL

PROCEDURE

  1. REMOVE RADIATOR SUPPORT OPENING COVER

  2. PRECAUTION

    Note:

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).

  3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).

  4. REMOVE REAR ENGINE UNDER COVER RH

  5. REMOVE NO. 2 CYLINDER HEAD COVER

  6. REMOVE V-RIBBED BELT

  7. REMOVE GENERATOR ASSEMBLY

    1. A340104

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the connector and detach the wire harness clamp.

    4. A340106

      Remove the 3 bolts, No. 2 generator bracket and generator assembly.

    5. A302303

      Remove the bolt and wire harness clamp bracket.