FRONT BLOWER MOTOR REMOVAL

PROCEDURE


  1. REMOVE FRONT DOOR SCUFF PLATE RH

    Tech Tips

    Use the same procedure as for the LH side.

    Click here

  2. REMOVE COWL SIDE TRIM BOARD RH

    Tech Tips

    Use the same procedure as for the LH side.

    Click here

  3. REMOVE NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY

    Click here

  4. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. B005M21

      Turn back the front floor carpet assembly as shown in the illustration.

    2. B005PUD

      Disengage the clamp.

    3. Disconnect the connector.

    4. B005LAJ

      Remove the 3 screws and blower motor with fan sub-assembly.

      Note


      • Replace the blower motor with fan sub-assembly if it has been dropped or subjected to a severe impact.

      • Do not apply excessive force to the blower motor with fan sub-assembly when removing it as it may be damaged.