COMPRESSOR(for 1WW) REMOVAL

PROCEDURE

  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

  2. REMOVE V-RIBBED BELT

  3. DISCONNECT SUCTION HOSE SUB-ASSEMBLY

    1. E320736

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the suction hose sub-assembly.

      Note:

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  4. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY

    1. E320737

      Remove the bolt and disconnect the discharge hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the discharge hose sub-assembly.

      Note:

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  5. REMOVE COMPRESSOR ASSEMBLY WITH PULLEY

    1. E320735

      Disconnect the connector.

    2. Disengage the clamp.

    3. E320738C01
      V100135

      Bolt

      V100136

      Nut

      Remove the bolt and 2 nuts.

    4. E320739

      Using an E8 "TORX" socket wrench, remove the 2 stud bolts.

    5. Remove the compressor assembly with pulley.