1ND-TV FUEL SERVICE DATA
Fuel pressure |
Normal condition |
19900 to 37000 kPa (Idling) |
Target common rail pressure |
Normal condition |
20800 to 180000 kPa (Engine running) |
Injector assembly |
Standard resistance |
150 to 210 kΩ at 20°C (68°F) |
Supply pump assembly (Suction control valve) |
Standard resistance |
2.60 to 3.15 Ω at 20°C (68°F) |
Supply pump assembly (Fuel temperature sensor) |
Standard resistance |
13.92 to 17.01 kΩ at -20°C (-4°F) |
5.31 to 6.49 kΩ at 0°C (32°F) |
||
2.25 to 2.75 kΩ at 20°C (68°F) |
||
1.06 to 1.29 kΩ at 40°C (104°F) |
||
0.54 to 0.66 kΩ at 60°C (140°F) |
||
0.29 to 0.36 kΩ at 80°C (176°F) |
||
0.17 to 0.20 kΩ at 100°C (212°F) |
||
Common rail assembly (Pressure Control Valve) |
Standard resistance |
3.42 to 3.78 Ω at 20°C (68°F) |
Fuel sender gauge assembly |
Standard resistance |
12.0 to 18.0 Ω (Float level F) |
12.0 to 415.0 Ω (Float level E to F) |
||
405.0 to 415.0 Ω (Float level E) |
||
Level warning switch |
Standard resistance (Float upper end position) |
Below 0.5 Ω |
Standard resistance (Float lower end position) |
1 MΩ or higher |