AIR CONDITIONING SYSTEM, Diagnostic DTC:B1419/19
| DTC Code | DTC Name |
|---|---|
| B1419/19 | Rear Room Temperature Sensor Circuit |
DESCRIPTION
The cooler thermistor (rear room temperature sensor) is installed in the rear panel. It detects the rear cabin temperature to control the air conditioning AUTO mode. The resistance of the cooler thermistor (rear room temperature sensor) changes in accordance with the rear cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (rear room temperature sensor) and reads voltage changes as the resistance of the cooler thermistor (rear room temperature sensor) changes.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
Memory |
Note |
|---|---|---|---|---|---|
B1419/19 |
Rear Room Temperature Sensor Circuit |
Open or short in the cooler thermistor (rear room temperature sensor) circuit. |
|
Stored (4 seconds or more) |
- |
WIRING DIAGRAM
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (REAR ROOM TEMPERATURE SENSOR)
Use the Data List to check if the rear room temperature sensor is functioning properly
Body Electrical > Air Conditioner > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Room Temp Sensor (Rear)
Cooler thermistor (rear room temperature sensor)
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear cabin temperature displayed
Open in the circuit: -6.5°C (- 20.3°F).
Short in the circuit: 57.25°C (135.05°F).
OK
The display is as specified in the normal condition column.
Result
Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
INSPECT COOLER THERMISTOR (REAR ROOM TEMPERATURE SENSOR)
Remove the cooler thermistor (rear room temperature sensor)
*a
Resistance
*b
Allowable Range
*c
Temperature
-
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
Note:Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tip:As the temperature increases, the resistance decreases (refer to the graph).
Result
Result
OK
NG
CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
Disconnect the G12 amplifier connector.
Disconnect the Q21 sensor connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
Q21-1 - G12-17 (TR)
Always
Below 1 Ω
Q21-2 - G12-7 (SG-6)
Always
Below 1 Ω
Q21-1 - Body ground
Always
10 kΩ or higher
Q21-2 - Body ground
Always
10 kΩ or higher
Result
Result
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR