DIFFERENTIAL PRESSURE SENSOR(w/o Glow Plug Controller) INSTALLATION

PROCEDURE

  1. INSTALL DIFFERENTIAL PRESSURE SENSOR ASSEMBLY

    1. A199756C01

      *1

      Vacuum Transmitting Hose Assembly

      *2

      No. 2 Vacuum Transmitting Hose Assembly

      *a

      View A

      *b

      Paint Mark (Yellow)

      *c

      Paint Mark (Pink)

      Connect the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly to the differential pressure sensor assembly and slide the 2 clips to secure them.

      Note:

      Connect the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly so that the paint marks of the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly are as shown in the illustration.

    2. A199754

      Install the differential pressure sensor assembly and bracket with the bolt .

      5.0 N*m

      51 kgf*cm

      44 in.*lbf

    3. A199667

      Connect the connector to the differential pressure sensor assembly.

  2. INSTALL OUTER COWL TOP PANEL (for LHD)

  3. INSTALL OUTER COWL TOP PANEL (for RHD)

  4. INSTALL NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for LHD)

  5. INSTALL NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for RHD)

  6. INSTALL WATER GUARD PLATE LH (for LHD)

  7. INSTALL WATER GUARD PLATE LH (for RHD)

  8. INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY

  9. INSTALL NO. 1 ENGINE COVER (w/ No. 1 Engine Cover)

  10. LEARNING DIFFERENTIAL PRESSURE SENSOR ASSEMBLY

    1. Start the engine and wait until the engine coolant temperature reaches 75°C (167°F) or more (A).

    2. Turn the ignition switch off and wait for 30 seconds or more (B).

    3. Repeat the above procedures (A) and (B) 3 times.

      Tip:
      • Procedures (A) and (B) must be repeated 3 times to complete the differential pressure sensor learning process.

      • If the differential pressure sensor learning is incomplete, DTC P244A may be stored.