VACUUM PUMP(for 3ZR-FAE) INSPECTION
PROCEDURE
INSPECT VACUUM PUMP VANE
-
*1
Vacuum Pump Vane Cap
*2
Vacuum Pump Vane
Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn out.
Tip:If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn out, replace the damaged parts with new ones.
-
Using a micrometer, measure length A of the vacuum pump vane with the vacuum pump vane caps removed.
Minimum length A
23.8 mm (0.937 in.)
Tip:If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.
Note:Measure the length 10 mm (0.394 in.) in from each end of the vacuum pump vane.
-
*1
Vacuum Pump Vane
*2
Vacuum Vane Cap
Using a vernier caliper, measure length B of the vacuum pump vane with the vacuum pump vane caps installed.
Minimum length B
76.0 mm (3.00 in.)
Tip:If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.
Note:Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps.
-
INSPECT VACUUM PUMP HOUSING
-
Check that the rotor part, coupling, vacuum pump housing or vacuum end cover is not damaged or excessively worn out.
Tip:If the rotor part, coupling, vacuum pump housing or vacuum end cover is damaged or excessively worn out, replace the vacuum pump assembly.
-