DIFFERENTIAL PRESSURE SENSOR(w/ Glow Plug Controller) INSTALLATION
PROCEDURE
INSTALL DIFFERENTIAL PRESSURE SENSOR ASSEMBLY
-
*1
No. 1 Vacuum Transmitting Hose Assembly
*2
No. 2 Vacuum Transmitting Hose Assembly
*a
View A
*b
Marked Yellow
*c
Marked Pink
Install the differential pressure sensor assembly to the sensor bracket with the bolt.
11 N*m
112 kgf*cm
8 ft.*lbf
Connect the No. 2 vacuum transmitting hose assembly to the differential pressure sensor assembly and slide the clip to secure it.
Connect the No. 1 vacuum transmitting hose assembly to the differential pressure sensor assembly and slide the clip to secure it.
Engage the guide to install the No. 2 wire harness heat insulator to the differential pressure sensor assembly.
Return the No. 2 wire harness heat insulator and engage the snap fastener.
Engage the clamp to connect the engine wire to the sensor bracket.
Connect the differential pressure sensor assembly connector.
-
INSTALL WIRE HARNESS CLAMP BRACKET
INSTALL NO. 1 WIRE HARNESS HEAT INSULATOR
INSTALL OUTER COWL TOP PANEL
for LHD:
for RHD:
INSTALL NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL
for LHD:
for RHD:
INSTALL WATER GUARD PLATE LH
for LHD:
for RHD:
INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY
INSTALL NO. 1 ENGINE COVER (w/ No. 1 Engine Cover)
LEARNING DIFFERENTIAL PRESSURE SENSOR ASSEMBLY
Start the engine and wait until the engine coolant temperature reaches 75°C (167°F) or more. (A)
Turn the ignition switch off and wait for 30 seconds or more. (B)
Repeat the above procedures (A) and (B) 3 times.
Tip:Procedures (A) and (B) must be repeated 3 times to complete the differential pressure sensor assembly learning process.
If the differential pressure sensor assembly learning is incomplete, DTC P244A may be stored.