AIR CONDITIONING SYSTEM Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)

DESCRIPTION

If there is a difference in temperature between the left and right air outlet while dual mode is ON, the following causes are possible.

Symptom Factor
There is a difference in temperature between the left and right air outlet (while cooling operation)
  • Cooler compressor assembly malfunction

  • Quantity of refrigerant gas lack

  • A/M damper and link operation (jamming)

  • Automatic light control sensor malfunction

There is a difference in temperature between the left and right air outlet (while heater operation)
  • Heater accessory assembly malfunction (low water)

  • A/M damper and link operation (jamming)

  • Heater core closed waterway

WIRING DIAGRAM

B006EMHE11
*a Air Conditioning Amplifier Assembly
*b Automatic Light Control Sensor
*c Main Body ECU (Multiplex Network Body ECU)
*d CAN Communication Line

CAUTION / NOTICE / HINT

Note


  • If DTC B1244 is output, troubleshoot for DTC B1244 first.

    Click here

  • Before replacing the main body ECU (multiplex network body ECU), refer to REGISTRATION.

PROCEDURE


  1. CHECK MALFUNCTION STATUS

    Result
    Result Proceed to
    While cooling A
    While heater B

    B
    A
  2. CHECK REFRIGERANT SHORTAGE


    1. Prepare the vehicle according to the table below.

      Measurement Condition:
      Item Condition
      A/C switch On
      Ambient temperature* 0 to 49°C (32 to 120°F)
      Blower speed HI

      *: If the ambient temperature is not within the range shown, do not perform this check.

    2. Connect the GTS to the DLC3.

    3. Turn the engine switch on (IG).

    4. Turn the GTS on.

    5. Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.


      Body Electrical > Air Conditioner > Utility
      Tester Display
      Refrigerant Gas Volume Check
      Result
      Result Amount of Refrigerant
      Refrigerant shortage Insufficient or leakage
      Refrigerant correct Correct
      OK
      "Refrigerant correct" is displayed on GTS.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. PERFORM ACTIVE TEST USING GTS (SERVO PULSE)


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Restrict Condition
      Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation

      Min.: 128

      Max.: 383

      Operates between 254 to 326 pulses
      Air Mix Servo Targ Pulse(P) No. 4 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation

      Min.: 128

      Max.: 383

      Operates between 186 and 258 pulses

      Body Electrical > Air Conditioner > Active Test
      Tester Display
      Air Mix Servo Targ Pulse(D)

      Body Electrical > Air Conditioner > Active Test
      Tester Display
      Air Mix Servo Targ Pulse(P)
      OK
      Damper servo motor is operated.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))


    1. Disconnect the G16 automatic light control sensor connector.

    2. Disconnect the G12 main body ECU (multiplex network body ECU) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G16-1 (CLTB) - G12-23 (CLTB) Always Below 1 Ω
      G16-2 (CLTE) - G12-25 (CLTE) Always Below 1 Ω
      G16-4 (CLTS) - G12-24 (CLTS) Always Below 1 Ω
      G16-1 (CLTB) or G12-23 (CLTB) - Other terminals and body ground Always 10 kΩ or higher
      G16-2 (CLTE) or G12-25 (CLTE) - Other terminals and body ground Always 10 kΩ or higher
      G16-4 (CLTS) or G12-24 (CLTS) - Other terminals and body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  5. INSPECT AUTOMATIC LIGHT CONTROL SENSOR


    1. Remove the automatic light control sensor.

      Click here

    2. Inspect the automatic light control sensor.

      Click here

      Result
      Proceed to
      OK
      NG

    OK
    NG
  6. PERFORM AIR OMISSION OF COOLANT

    Click here

    Result
    Proceed to
    NEXT

    NEXT
  7. CHECK OPERATION (AIR CONDITIONING SYSTEM)


    1. Check that there is not a difference in temperature between the left and right air outlet.

      OK
      There is not a difference in temperature between the left and right air outlet.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  8. PERFORM ACTIVE TEST USING GTS (AIR MIX SERVO TARG PULSE (D), AIR MIX SERVO TARG PULSE (P))


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Restrict Condition
      Air Mix Servo Targ Pulse(D)

        for LHD:

      • No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation


        for RHD:

      • No. 4 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation

      Min.: 128

      Max.: 383


        for LHD:

      • Operates between 254 to 326 pulses


        for RHD:

      • Operates between 186 to 258 pulses

      Air Mix Servo Targ Pulse(P)

        for LHD:

      • No. 4 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation


        for RHD:

      • No. 6 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation

      Min.: 128

      Max.: 383


        for LHD:

      • Operates between 186 to 258 pulses


        for RHD:

      • Operates between 254 to 326 pulses


      Body Electrical > Air Conditioner > Active Test
      Tester Display
      Air Mix Servo Targ Pulse(D)

      Body Electrical > Air Conditioner > Active Test
      Tester Display
      Air Mix Servo Targ Pulse(P)
      OK
      Damper servo motor is operated.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  9. INSPECT HEATER ACCESSORY ASSEMBLY


    1. Remove the heater accessory assembly.

      Click here

    2. Inspect the heater accessory assembly.

      Click here

      Result
      Proceed to
      OK
      NG

    OK
    NG