OUTER MIRROR SWITCH INSPECTION
PROCEDURE
INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Power Retract Mirror)
Check the mirror select switch and mirror surface adjust switch.
-
*1
Mirror Select Switch
*2
Mirror Surface Adjust Switch
*a
Component without harness connected
(Outer Mirror Switch Assembly)
Turn the mirror select switch to the L position.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (for left side)
Tester Connection
Condition
Specified Condition
16 (VL) - 22 (B)
19 (M+) - 20 (E)
UP
Below 1 Ω
OFF
10 kΩ or higher
16 (VL) - 20 (E)
19 (M+) - 22 (B)
DOWN
Below 1 Ω
OFF
10 kΩ or higher
17 (HL) - 22 (B)
19 (M+) - 20 (E)
LEFT
Below 1 Ω
OFF
10 kΩ or higher
17 (HL) - 20 (E)
19 (M+) - 22 (B)
RIGHT
Below 1 Ω
OFF
10 kΩ or higher
Turn the mirror select switch to the R position.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (for right side)
Tester Connection
Condition
Specified Condition
15 (VR) - 22 (B)
19 (M+) - 20 (E)
UP
Below 1 Ω
OFF
10 kΩ or higher
15 (VR) - 20 (E)
19 (M+) - 22 (B)
DOWN
Below 1 Ω
OFF
10 kΩ or higher
14 (HR) - 22 (B)
19 (M+) - 20 (E)
LEFT
Below 1 Ω
OFF
10 kΩ or higher
14 (HR) - 20 (E)
19 (M+) - 22 (B)
RIGHT
Below 1 Ω
OFF
10 kΩ or higher
If the result is not as specified, replace the outer mirror switch assembly.
-
INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Power Retract Mirror)
Check the mirror select switch and mirror surface adjust switch.
-
*1
Mirror Select Switch
*2
Mirror Surface Adjust Switch
*3
Retract Switch
*a
Component without harness connected
(Outer Mirror Switch Assembly)
Turn the mirror select switch to the L position.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (for left side)
Tester Connection
Condition
Specified Condition
16 (VL) - 22 (B)
19 (M+) - 20 (E)
UP
Below 1 Ω
OFF
10 kΩ or higher
16 (VL) - 20 (E)
19 (M+) - 22 (B)
DOWN
Below 1 Ω
OFF
10 kΩ or higher
17 (HL) - 22 (B)
19 (M+) - 20 (E)
LEFT
Below 1 Ω
OFF
10 kΩ or higher
17 (HL) - 20 (E)
19 (M+) - 22 (B)
RIGHT
Below 1 Ω
OFF
10 kΩ or higher
Turn the mirror select switch to the R position.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (for right side)
Tester Connection
Condition
Specified Condition
15 (VR) - 22 (B)
19 (M+) - 20 (E)
UP
Below 1 Ω
OFF
10 kΩ or higher
15 (VR) - 20 (E)
19 (M+) - 22 (B)
DOWN
Below 1 Ω
OFF
10 kΩ or higher
14 (HR) - 22 (B)
19 (M+) - 20 (E)
LEFT
Below 1 Ω
OFF
10 kΩ or higher
14 (HR) - 20 (E)
19 (M+) - 22 (B)
RIGHT
Below 1 Ω
OFF
10 kΩ or higher
If the result is not as specified, replace the outer mirror switch assembly.
-
Check the retract switch.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
If the result is not as specified, replace the outer mirror switch assembly.
Tester Connection
Condition
Specified Condition
24 (MF) - 20 (E)
23 (MR) - 22 (B)
Pushed in
Below 1 Ω
24 (MF) - 22 (B)
23 (MR) - 20 (E)
Not pushed in
Below 1 Ω
If the result is not as specified, replace the outer mirror switch assembly.