| DTC Code | DTC Name |
|---|---|
| P0A9D-123 | Hybrid Battery Temperature Sensor "A" Circuit Low |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC7-123 | Hybrid Battery Temperature Sensor "B" Circuit Low |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACC-123 | Hybrid Battery Temperature Sensor "C" Circuit Low |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AEA-123 | Hybrid Battery Temperature Sensor "D" Circuit Low |
| P0AEB-123 | Hybrid Battery Temperature Sensor "D" Circuit High |
| P0BC4-123 | Hybrid Battery Temperature Sensor "E" Circuit Low |
| P0BC5-123 | Hybrid Battery Temperature Sensor "E" Circuit High |
| P0C35-123 | Hybrid Battery Temperature Sensor "F" Circuit Low |
| P0C36-123 | Hybrid Battery Temperature Sensor "F" Circuit High |
DESCRIPTION
Refer to the description for DTC P0A9C-123 Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A9D P0A9E P0AC7 P0AC8 P0ACC P0ACD P0AEA P0AEB P0BC4 P0BC5 P0C35 P0C36 |
123 | When the temperature of the battery temperature sensor is less than the standard value (open) or higher than the standard value (shorted) (1 trip detection). |
|
Tech Tips
After checking for the above DTCs, check the hybrid system Data List item "Temp of Batt" using the GTS.
| Temperature Displayed | Malfunction |
|---|---|
| Below -45°C (-49°F) | Open or +B short circuit |
| 95°C (203°F) or more | GND short circuit |
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0A9C-123 Click here.
Refer to the wiring diagram for DTC P0ABF-123 Click here.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection Click here
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
Tech Tips
If a short to +B occurs in the battery temperature sensor, battery current sensor or intake air temperature sensor, the following DTCs may be output simultaneously.
| DTC No. | Relevant Diagnosis |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AEB-123 | Hybrid Battery Temperature Sensor "D" Circuit High |
| P0BC5-123 | Hybrid Battery Temperature Sensor "E" Circuit High |
| P0C36-123 | Hybrid Battery Temperature Sensor "F" Circuit High |
| P0AAF-123 | Hybrid Battery Pack Air Temperature Sensor "A" Circuit High |
| P0AB4-123 | Hybrid Battery Pack Air Temperature Sensor "B" Circuit High |
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (P31AB-123) Click here |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (P0AFC-123) Click here |
| A |
|
READ VALUE USING GTS
Connect the GTS to the DLC3.
Enter the following menus: Powertrain / Hybrid Control / Data List / Temp of Batt TB 1 to 6.
Tech Tips
Compare the temperature of the 6 battery temperature sensors to determine the sensor with the malfunction (Temp of Batt TB1 to TB6).
| NEXT |
|
CHECK CONNECTOR CONNECTION CONDITION (BATTERY TEMPERATURE SENSOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly Click here.
Check the connections of the z24 connector of the battery smart unit.
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
Install the No. 1 hybrid battery shield sub-assembly.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HV BATTERY (BATTERY TEMPERATURE SENSOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly Click here.
Disconnect the z24 battery smart unit connector.
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
Measure the resistance of the circuit for the malfunctioning sensor (battery temperature sensor 0 to 5).
| Tester Connection | Battery Temperature Sensor No. |
|---|---|
| z24-13 (TB0) - z24-1 (GB0) | 0 |
| z24-14 (TB1) - z24-2 (GB1) | 1 |
| z24-15 (TB2) - z24-3 (GB2) | 2 |
| z24-16 (TB3) - z24-4 (GB3) | 3 |
| z24-17 (TB4) - z24-5 (GB4) | 4 |
| z24-18 (TB5) - z24-6 (GB5) | 5 |
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the z24 battery smart unit connector.
Install the No. 1 hybrid battery shield sub-assembly.
| NG |
|
REPLACE HV BATTERY Click here |
| OK |
|
CHECK BATTERY SMART UNIT (VIB VOLTAGE)
Note
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly Click here.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| *a | Component with harness connected (Battery Smart Unit) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
| OK |
|
REPLACE BATTERY SMART UNIT Click here |
| NG |
|
CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (BATTERY CURRENT SENSOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly Click here.
Disconnect the z25 hybrid battery junction block assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| *a | Front view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the z25 hybrid battery junction block assembly connector.
Install the No. 2 hybrid battery shield sub-assembly.
| OK |
|
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY Click here |
| NG |
|
CHECK HARNESS AND CONNECTOR (BATTERY SMART UNIT - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
Note
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly Click here.
Disconnect the z25 hybrid battery junction block assembly connector.
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
| *b | Front view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Disconnect the z24 battery smart unit connector.
Measure the resistance according to the value(s) in the tables below.
| Standard Resistance (Check for Open) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the z25 hybrid battery junction block assembly connector.
Reconnect the z24 battery smart unit connector.
Install the No. 2 hybrid battery shield sub-assembly.
| OK |
|
REPLACE BATTERY SMART UNIT Click here |
| NG |
|
REPAIR HARNESS OR CONNECTOR OR REPLACE HV BATTERY |