8NR-FTS INTAKE / EXHAUST SERVICE DATA

Table 1. COOLANT

Standard Capacity

Classification

2.1 liters (2.2 US qts, 1.8 Imp. qts)

Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).

Table 2. TURBOCHARGER

Boost pressure

Standard

120 kPa (1.2 kgf/cm2, 17 psi) or higher

Turbine with valve housing sub-assembly

Warpage

Standard

0.15 mm (0.00591 in.) or less

Waste gate valve

Clearance

Standard

0.15 mm (0.00591 in.)

Turbine shaft

Axial play

Standard

0.15 mm (0.00591 in.) or less

Waste gate valve actuator

Travel

Standard

15 mm (0.591 in.) or more

Intake air control valve (air by-pass valve assembly)

Tester Connection

1 - 2

Condition

20°C (68°F)

Specified Condition

8.7 to 9.2 Ω

Table 3. EXHAUST PIPE

Compression spring

Exhaust manifold converter sub-assembly (TWC: Front Catalyst) x Front exhaust pipe sub-assembly (TWC: Rear Catalyst)

Standard length

43 mm (1.69 in.)

Minimum free length

41.5 mm (1.63 in.)

Front exhaust pipe sub-assembly (TWC: Rear Catalyst) x Tail exhaust pipe assembly

Standard length

40 mm (1.57 in.)

Minimum free length

38.5 mm (1.52 in.)

Table 4. RESERVE TANK CAP (for Intercooler)

Item

Specified Condition

Standard pressure (for brand-new reserve tank cap (for Intercooler))

93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18 psi)

Minimum pressure (for used reserve tank cap (for Intercooler))

79 kPa (0.8 kgf/cm2, 11.5 psi)