AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) CHECK MODE PROCEDURE
REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)
Start the engine.
Check that the A/C switch indicator remains on when the following conditions are met.
*A
for Hatchback, Wagon (for LHD)
*B
for Hatchback, Wagon (for RHD)
*C
for Sedan (for LHD)
*D
for Sedan (for RHD)
Table 1. Measurement Condition Item
Condition
A/C switch
On
A/C operation time
15 minutes or more
Ambient temperature*
0 to 49°C (32 to 120°F)
Engine coolant temperature
45°C (113°F) or more
*: If the ambient temperature is not within the range shown, do not perform this check.
Tip:The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.
Connect the GTS to the DLC3.
Check for DTC B14B8.
Table 2. Result Result
Amount of Refrigerant
Corrective Action
DTC B14B8 is output
Empty or nearly empty
Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
DTC B14B8 is not output
Correct or insufficient
Perform a refrigerant shortage check using the GTS.
REFRIGERANT SHORTAGE CHECK USING GTS
Connect the GTS to the DLC3.
Start the engine.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
According to the display on the GTS, perform the refrigerant shortage check when the following conditions are met.
Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
Table 3. Measurement Condition Item
Condition
A/C switch
On
Ambient temperature*
0 to 49°C (32 to 120°F)
Blower speed
HI
*: If the ambient temperature is not within the range shown, do not perform this check.
Tip:Refer to the GTS operator's manual for further details.
A message indicating a refrigerant shortage is displayed on the GTS and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
DTCs are not stored when performing the refrigerant shortage check using the GTS.
Table 4. Result Result
Amount of Refrigerant
Corrective Action
Refrigerant shortage
Insufficient or leakage
Check for refrigerant leaks using a halogen leak detector, and repair if necessary.
Evacuate the air conditioning system and charge it with the appropriate volume of new or purified refrigerant.
Refrigerant correct
Correct
-