AIR CONDITIONING SYSTEM, Diagnostic DTC:B1417/17
| DTC Code | DTC Name |
|---|---|
| B1417/17 | Rear Evaporator Temperature Sensor Circuit |
DESCRIPTION
The No. 2 air conditioning harness assembly (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the cooled air temperature that has passed through the evaporator and to control the rear air conditioning. It sends signals to the air conditioning amplifier assembly. The signals change in accordance with the resistance of the No. 2 air conditioning harness assembly (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier assembly applies a voltage (5 V) to the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) and reads voltage changes as the resistance of the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) changes. This sensor is used for frost prevention.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
Memory |
Note |
|---|---|---|---|---|---|
B1417/17 |
Rear Evaporator Temperature Sensor Circuit |
Open or short in the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) circuit. |
|
Stored (4 seconds or more) |
- |
WIRING DIAGRAM
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (REAR EVAPORATOR TEMPERATURE SENSOR)
Use the Data List to check if the rear evaporator temperature sensor is functioning properly
Table 1. Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sens (Rear)
Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual rear evaporator temperature displayed
Open in the circuit: -29.7°C (- 21.46°F).
Short in the circuit: 59.55°C (139.19°F).
OK
The display is as specified in the normal condition column.
Result
Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
INSPECT NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (REAR EVAPORATOR TEMPERATURE SENSOR)
Remove the No. 2 air conditioning harness assembly (rear evaporator temperature sensor)
*a
Sensing Portion
*b
Resistance
*c
Allowable Range
*d
Temperature
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
7 (-) - 8 (+)
-10°C (14°F)
7.30 to 9.10 kΩ
-5°C (23°F)
5.65 to 6.95 kΩ
0°C (32°F)
4.40 to 5.35 kΩ
5°C (41°F)
3.40 to 4.15 kΩ
10°C (50°F)
2.70 to 3.25 kΩ
15°C (59°F)
2.14 to 2.58 kΩ
20°C (68°F)
1.71 to 2.05 kΩ
25°C (77°F)
1.38 to 1.64 kΩ
30°C (86°F)
1.11 to 1.32 kΩ
Note:Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tip:As the temperature increases, the resistance decreases (refer to the graph).
Result
Result
OK
NG
CHECK HARNESS AND CONNECTOR (REAR EVAPORATOR TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
Disconnect the Q13 harness connector.
Disconnect the G12 amplifier connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
Q13-8 (+) - G12-4 (TEC)
Always
Below 1 Ω
Q13-7 (-) - G12-19 (SGND)
Always
Below 1 Ω
Q13-8 (+) - Body ground
Always
10 kΩ or higher
Q13-7 (-) - Body ground
Always
10 kΩ or higher
Result
Result
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR