CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P2769 and P2770
| DTC Code | DTC Name |
|---|---|
| P2769 | Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
| P2770 | Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
DESCRIPTION
Based on the signal received by the shift solenoid valve SL, the ECM uses the shift solenoid valve SLU to control the lock-up clutch pressure.
If there is an open or short in the shift solenoid valve SL circuit, the ECM stops sending current to the defective shift solenoid valve.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
MIL |
Memory |
|---|---|---|---|---|---|
P2769 |
Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on |
DTC stored |
P2770 |
Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) |
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on |
DTC stored |
MONITOR DESCRIPTION
These DTCs indicate an open or short in the shift solenoid valve SL circuit. If there is an open or short in the shift solenoid valve SL circuit, the ECM detects the problem, illuminates the MIL and stores a DTC.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Perform initialization when parts related to the continuously variable transaxle are replaced.
Check that no DTCs are stored after performing initialization.
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
-
*a
Component without harness connected
(Transmission Wire)
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
12 (SL) - Body ground
20°C (68°F)
11 to 15 Ω
Result
Proceed to
OK
NG
NG REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLYClick here
-
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
-
*a
Front view of wire harness connector
(to ECM)
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
B93-67 (SL) - Body ground
20°C (68°F)
11 to 15 Ω
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)
-
REPLACE ECM
Replace the ECM.
Result
Proceed to
NEXT
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly.
Result
Proceed to
NEXT