PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE PIPING CLAMP
| *1 | Liquid Tube Sub-assembly |
| *2 | Air Conditioner Tube and Accessory Assembly |
Install SST to the piping clamp as shown in the illustration.
| *a | Push in |
Hold the air conditioner tube and accessory assembly and liquid tube sub-assembly with each hand and push in SST with both thumbs.
Note
Do not apply excessive force to the air conditioner tube and accessory assembly or liquid tube sub-assembly as they may bend.
| *1 | Air Conditioner Tube and Accessory Assembly |
| *a | Stopper |
| *b | Pull off |
Raise the stopper of SST and remove SST and the piping clamp together from the air conditioner tube and accessory assembly.
Remove the piping clamp from SST.
Remove the air conditioner tube and accessory assembly from the liquid tube sub-assembly.
Remove the 2 O-rings from the liquid tube sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.