AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) PROBLEM SYMPTOMS TABLE
Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.
Inspect the fuses and relays related to this system before inspecting the suspected areas below.
Symptom |
Suspected Area |
Link |
|---|---|---|
All functions of the A/C system do not operate |
IG power source circuit |
|
Back-up power source circuit |
||
LIN communication circuit |
||
Air conditioning amplifier assembly |
||
Air flow control: No blower operation |
Blower motor circuit |
|
LIN communication circuit |
||
Air conditioning amplifier assembly |
||
Air flow control: No blower control |
Blower motor circuit |
|
LIN communication circuit |
||
Air conditioning amplifier assembly |
||
Air flow control: Insufficient air flow |
Blower motor circuit |
|
Air conditioning amplifier assembly |
||
Temperature control: Cooling effectiveness is poor |
Refrigerant shortage check using the GTS |
|
Refrigerant volume |
- |
|
Refrigerant pressure*11 |
||
Refrigerant pressure*12 |
||
Cooler expansion valve |
||
Compressor assembly with pulley*4 |
||
Compressor assembly with pulley*5 |
||
Compressor assembly with pulley*6 |
||
Compressor assembly with pulley*7, *8 |
||
Compressor assembly with pulley*9 |
||
Compressor assembly with pulley*10 |
||
Air conditioning amplifier assembly |
||
Temperature control: No cool air comes out |
Refrigerant shortage check using the GTS |
|
Refrigerant volume |
- |
|
Refrigerant pressure*11 |
||
Refrigerant pressure*12 |
||
Air conditioning pressure sensor circuit |
||
Compressor solenoid circuit |
||
Air mix damper control servo motor circuit (for driver side)*1 |
||
Air mix damper control servo motor circuit (for front passenger side)*1 |
||
Air mix damper control servo motor circuit*2 |
||
Evaporator temperature sensor circuit |
||
Room temperature sensor circuit |
||
Ambient temperature sensor circuit |
||
LIN communication circuit |
||
Cooler expansion valve |
||
Air mix damper control servo motor (for driver side)*1 |
||
Air mix damper control servo motor (for front passenger side)*1 |
||
Air mix damper control servo motor*2 |
||
Air conditioning harness assembly |
||
Air conditioning amplifier assembly |
||
ECM*4 |
||
ECM*5 |
||
ECM*6 |
||
ECM*7 |
||
ECM*8 |
||
ECM*9 |
||
ECM*10 |
||
Temperature control: No warm air comes out |
Air mix damper control servo motor circuit (for driver side)*1 |
|
Air mix damper control servo motor circuit (for front passenger side)*1 |
||
Air mix damper control servo motor circuit*2 |
||
Evaporator temperature sensor circuit |
||
Room temperature sensor circuit |
||
Ambient temperature sensor circuit |
||
PTC heater circuit*3 |
||
LIN communication circuit |
||
Air mix damper control servo motor (for driver side)*1 |
||
Air mix damper control servo motor (for front passenger side)*1 |
||
Air mix damper control servo motor*2 |
||
Air conditioning harness assembly |
||
Air conditioning amplifier assembly |
||
ECM*4 |
||
ECM*5 |
||
ECM*6 |
||
ECM*7 |
||
ECM*8 |
||
ECM*9 |
||
ECM*10 |
||
Temperature control: Output air is warmer or cooler than the set temperature or response is slow |
Refrigerant shortage check using the GTS |
|
Refrigerant volume |
- |
|
Refrigerant pressure*11 |
||
Refrigerant pressure*12 |
||
Compressor solenoid circuit |
||
Solar sensor circuit (for driver side)*1 |
||
Solar sensor circuit (for front passenger side)*1 |
||
Solar sensor circuit*2 |
||
Room temperature sensor circuit |
||
Ambient temperature sensor circuit |
||
Air mix damper control servo motor circuit (for driver side)*1 |
||
Air mix damper control servo motor circuit (for front passenger side)*1 |
||
Air mix damper control servo motor circuit*2 |
||
Air inlet damper control servo motor circuit |
||
PTC heater circuit*3 |
||
LIN communication circuit |
||
Heater radiator unit sub-assembly |
||
Cooler expansion valve |
||
Air mix damper control servo motor (for driver side)*1 |
||
Air mix damper control servo motor (for front passenger side)*1 |
||
Air mix damper control servo motor*2 |
||
Air inlet damper control servo motor |
||
Air conditioning harness assembly |
||
Air conditioning amplifier assembly |
||
ECM*4 |
||
ECM*5 |
||
ECM*6 |
||
ECM*7 |
||
ECM*8 |
||
ECM*9 |
||
ECM*10 |
||
Temperature control: No temperature control (only MAX COLD or MAX HOT) |
Air mix damper control servo motor circuit (for driver side)*1 |
|
Air mix damper control servo motor circuit (for front passenger side)*1 |
||
Air mix damper control servo motor circuit*2 |
||
Room temperature sensor circuit |
||
Ambient temperature sensor circuit |
||
Evaporator temperature sensor circuit |
||
Solar sensor circuit (for driver side)*1 |
||
Solar sensor circuit (for front passenger side)*1 |
||
Solar sensor circuit*2 |
||
LIN communication circuit |
||
Air mix damper control servo motor (for driver side)*1 |
||
Air mix damper control servo motor (for front passenger side)*1 |
||
Air mix damper control servo motor*2 |
||
Air conditioning harness assembly |
||
Air conditioning amplifier assembly |
||
Temperature control: Output air temperature is different between left and right registers (the set temperature is the same for both)*1 |
Refrigerant shortage check using the GTS |
|
Refrigerant volume |
- |
|
Refrigerant pressure*11 |
||
Refrigerant pressure*12 |
||
Air mix damper control servo motor circuit (for driver side) |
||
Air mix damper control servo motor circuit (for front passenger side) |
||
Solar sensor circuit (for driver side) |
||
Solar sensor circuit (for front passenger side) |
||
Air mix damper control servo motor (for driver side) |
||
Air mix damper control servo motor (for front passenger side) |
||
Air conditioning harness assembly |
||
Air conditioning amplifier assembly |
||
No air inlet control |
Air inlet damper control servo motor circuit |
|
LIN communication circuit |
||
Air inlet damper control servo motor |
||
Air conditioning harness assembly |
||
Air conditioning amplifier assembly |
||
No air flow mode control |
Air outlet damper control servo motor circuit |
|
Air outlet damper control servo motor |
||
Air conditioning harness assembly |
||
LIN communication circuit |
||
Air conditioning amplifier assembly |
||
Quick heater assembly does not operate*3 |
PTC heater circuit |
|
Air conditioning amplifier assembly |
||
Diagnostic Trouble Codes (DTCs) are not recorded. Set mode is cleared when the ignition switch is turned off |
Back-up power source circuit |
|
Air conditioning amplifier assembly |
*1: for Dual Type
*2: for Single Type
*3: w/ PTC Heater
*4: for 1WW
*5: for 1ND-TV
*6: for 1NR-FE
*7: for 1ZR-FAE
*8: for 1ZR-FE
*9: for 2ZR-FE
*10: for 8NR-FTS
*11: for HFC-134a (R134a)
*12: for HFO-1234yf (R1234yf)