VACUUM REGULATING VALVE INSPECTION
PROCEDURE
INSPECT VACUUM REGULATING VALVE ASSEMBLY
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
11.1 to 12.5 Ω
If the result is not as specified, replace the vacuum regulating valve assembly.
Inspect vacuum regulating valve operation.
-

Air
Check that air flows from port E to G.
-
*1
Filter

Air
Apply battery voltage across terminals 1 and 2 as shown in the illustration.
Check that air flows from port E to the filter.
If the result is not as specified, replace the vacuum regulating valve assembly.
-