AUTOMATIC TRANSMISSION SYSTEM (for 2KD-FTV), Diagnostic DTC:P0818

DTC Code DTC Name
P0818 Driveline Disconnect Switch Input Circuit

DESCRIPTION

The TCM detects the signal from the transfer neutral position switch.

This DTC indicates that the transfer neutral position switch remains ON.

DTC Code DTC Detection Condition Trouble Area
P0818

Transfer neutral position switch remains ON while vehicle is running under following conditions for 30 sec. (2-trip detection logic):


  • Vehicle speed is 25 km/h (16 mph) or more

  • Transfer shift lever is on H


  • Short in transfer neutral position switch circuit

  • Transfer neutral position switch

  • TCM

MONITOR DESCRIPTION

The TCM detects whether or not the transfer shift lever is in neutral by monitoring the signal from the transfer neutral position switch.

If the transfer neutral position switch indicates that the transfer shift lever is in neutral under all of the following conditions, the TCM will conclude that there is a malfunction of the transfer neutral position switch.


Then the TCM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

A01DW7YE50

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (NO. 2 TRANSFER INDICATOR SWITCH - BODY GROUND)


    1. A01E1XPE10
      Text in Illustration
      *a

      Front view of wire harness connector

      (to No. 2 Transfer Indicator Switch)

      Disconnect the No. 2 Transfer Indicator Switch connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      T5-2 - Body ground Always Below 1 Ω

    NG
    OK
  2. INSPECT NO. 2 TRANSFER INDICATOR SWITCH (TRANSFER NEUTRAL POSITION SWITCH)


    1. A01DXH1E01
      Text in Illustration
      *a

      Component without harness connected

      (No. 2 Transfer Indicator Switch)

      *b Pushed
      *c Not pushed

      Remove the No. 2 transfer indicator switch.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - 2 Not pushed 10 kΩ or higher
      1 - 2 Pushed Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (NO. 2 TRANSFER INDICATOR SWITCH - TCM)


    1. Disconnect the T5 No. 2 Transfer Indicator Switch connector.

    2. Disconnect the T37 TCM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      T5-1 - T37-16 (TFN) Always Below 1 Ω
      T5-1 or T37-16 (TFN) - Body ground Always 10 kΩ or higher

    NG
    OK