2GR-FKS BATTERY / CHARGING SERVICE DATA

Battery Standard voltage 12.5 to 12.9 V at 20°C (68°F)
Fuse Standard resistance Below 1 Ω
Charging circuit without load Standard amperage 10 A or higher
Standard voltage 13.2 to 14.8 V
Charging circuit with load Standard amperage 30 A or higher
Generator brush holder assembly 180A Type
Brush length Standard exposed brush length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed brush length 4.5 mm (0.177 in.)
Generator rotor assembly 180A Type
Tester Connection Condition Specified Condition
Slip ring - Slip ring Approx. 20°C (68°F) 1.9 to 2.3 Ω
Slip ring - Rotor Always 1 MΩ or higher
Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)