SUSPENSION CONTROL SERVICE DATA

No. 1 Height Control Compressor (Exhaust Valve)
Tester Connection Condition Specified Condition
L182-1 (L) - L182-2 (B) at 20°C (68°F) 9.36 to 10.14 Ω

Battery positive (+) → L182-1 (-)

Battery negative (-) → L182-2 (+)

- Operates (operating sound heard)
No. 1 Height Control Compressor (Compressor Motor)
Tester Connection Condition Specified Condition

Battery positive (+) → P10-1 (B)

Battery negative (-) → P10-2 (E)

- Operates (operating sound heard)
No. 3 Height Control Valve
Tester Connection Condition Specified Condition
L181-1 (SMTI) - L181-2 (E1) at 20°C (68°F) 9.36 to 10.14 Ω
L181-3 (SMSI) - L181-2 (E1) at 20°C (68°F) 9.36 to 10.14 Ω
L183-1 (SMOS) - L183-2 (E2) at 20°C (68°F) 9.36 to 10.14 Ω
L183-3 (SMTO) - L183-2 (E2) at 20°C (68°F) 9.36 to 10.14 Ω

Battery positive (+) → L181-1 (SMTI)

Battery negative (-) → L181-2 (E1)

- Operates (operating sound heard)

Battery positive (+) → L181-3 (SMSI)

Battery negative (-) → L181-2 (E1)

- Operates (operating sound heard)

Battery positive (+) → L183-1 (SMOS)

Battery negative (-) → L183-2 (E2)

- Operates (operating sound heard)

Battery positive (+) → L183-3 (SMTO)

Battery negative (-) → L183-2 (E2)

- Operates (operating sound heard)
Height Control Pressure Sensor
Tester Connection Condition Specified Condition
L3-2 (PACC) - L3-3 (SHB) Apply 5 V between terminals 1 (SHG) and 3 (SHB). 0.5 to 4.5 V
Height Control Way
Tester Connection Condition Specified Condition
A42-2 (PAC2) - A42-3 (SHB) Apply 5 V between terminals 1 (SHG) and 3 (SHB). 0.5 to 4.5 V
Height Control Compressor Thermistor Assembly
Tester Connection Condition Specified Condition
L180-1 (SBL) - L180-2 (TOIL) 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ
Control Valve Assembly (for Front Side)
Tester Connection Condition Specified Condition
A38-1 (RH+) - A38-2 (E) at 20°C (68°F) 9.36 to 10.14 Ω
A38-3 (LH+) - A38-2 (E) at 20°C (68°F) 9.36 to 10.14 Ω

Battery positive (+) → A38-1 (RH+)

Battery negative (-) → A38-2 (E)

- Sound of No. 1 height control valve operating can be heard

Battery positive (+) → A38-3 (LH+)

Battery negative (-) → A38-2 (E)

- Sound of No. 1 height control valve operating can be heard
Control Valve Assembly (for Rear Side)
Tester Connection Condition Specified Condition
L177-1 (RH+) - L177-2 (E) at 20°C (68°F) 9.36 to 10.14 Ω
L177-3 (LH+) - L177-2 (E) at 20°C (68°F) 9.36 to 10.14 Ω

Battery positive (+) → L177-1 (RH+)

Battery negative (-) → L177-2 (E)

- Sound of No. 2 height control valve operating can be heard

Battery positive (+) → L177-3 (LH+)

Battery negative (-) → L177-2 (E)

- Sound of No. 2 height control valve operating can be heard
Height Control Sensor (for Front Side)
Tester Connection Condition Specified Condition

for 2WD:

for LH Side

A74-2 (SHFL) - A74-1 (SHG) +30° (High) 3.45 V

for 2WD:

for LH Side

A74-2 (SHFL) - A74-1 (SHG) 0° (Standard position) 2.25 V

for 2WD:

for LH Side

A74-2 (SHFL) - A74-1 (SHG) -30° (Low) 1.05 V

for 2WD:

for RH Side

A75-2 (SHFR) - A75-1 (SHG) +30° (High) 3.45 V

for 2WD:

for RH Side

A75-2 (SHFR) - A75-1 (SHG) 0° (Standard position) 2.25 V

for 2WD:

for RH Side

A75-2 (SHFR) - A75-1 (SHG) -30° (Low) 1.05 V

for AWD:

for LH Side

A68-2 (SHFL) - A68-1 (SHG) +30° (High) 3.45 V

for AWD:

for LH Side

A68-2 (SHFL) - A68-1 (SHG) 0° (Standard position) 2.25 V

for AWD:

for LH Side

A68-2 (SHFL) - A68-1 (SHG) -30° (Low) 1.05 V

for AWD:

for RH Side

A69-2 (SHFR) - A69-1 (SHG) +30° (High) 3.45 V

for AWD:

for RH Side

A69-2 (SHFR) - A69-1 (SHG) 0° (Standard position) 2.25 V

for AWD:

for RH Side

A69-2 (SHFR) - A69-1 (SHG) -30° (Low) 1.05 V
Height Control Sensor (for Rear Side)
Tester Connection Condition Specified Condition
for LH Side +45° (High) 4.1 V
for LH Side 0° (Standard position) 2.25 V
for LH Side -45° (Low) 0.45 V
for RH Side +45° (High) 4.1 V
for RH Side 0° (Standard position) 2.25 V
for RH Side -45° (Low) 0.45 V
Front Acceleration Sensor
Tester Connection Condition Specified Condition
for LH Side L47-1 (SGFL) - L47-2 (SGG) Sensor stationary Approx. 2.0 to 2.5 V
for LH Side L47-1 (SGFL) - L47-2 (SGG) Sensor vibrating vertically Changes between approx. 0.9 and 3.6 V
for RH Side L36-1 (SGFR) - L36-2 (SGG) Sensor stationary Approx. 2.0 to 2.5 V
for RH Side L36-1 (SGFR) - L36-2 (SGG) Sensor vibrating vertically Changes between approx. 0.9 and 3.6 V
Absorber Control Actuator (for Front Side)
Tester Connection Condition Specified Condition

for 2WD:

for LH Side

A14-1 (FAL-) - A14-2 (FAL+) 15 to 25°C 2.8 to 4.4 Ω

for 2WD:

for RH Side

A23-1 (FAR-) - A23-2 (FAR+) 15 to 25°C 2.8 to 4.4 Ω

for AWD:

for LH Side

A70-1 (FAL-) - A70-3 (FAL+) 15 to 25°C 2.8 to 4.4 Ω

for AWD:

for RH Side

A71-1 (FAR-) - A71-3 (FAR+) 15 to 25°C 2.8 to 4.4 Ω
Absorber Control Actuator (for Rear Side)
Tester Connection Condition Specified Condition
for LH side L75-1 (RAL+) - L75-3 (RAL-) 15 to 25°C 2.8 to 4.4 Ω
for RH side z25-1 (RAR+) - z25-3 (RAR-) 15 to 25°C 2.8 to 4.4 Ω
Satellite Switch Set (Absorber Control Switch)
Tester Connection Switch Condition Specified Condition
G49-3 (P) - G49-7 (GND) Combination switch assembly knob turned and held at S/S+ position Below 50 Ω
G49-3 (P) - G49-7 (GND) Combination switch assembly knob not turned to S/S+ position 10 kΩ or higher
G49-2 (B) - G49-7 (GND) Normal/Custom mode switch pushed and held Below 50 Ω
G49-2 (B) - G49-7 (GND) Normal/Custom mode switch not pushed 10 kΩ or higher
Integration Control and Panel Assembly (Height Control Switch)
Tester Connection Switch Condition Specified Condition
G72-4 (HSW) - G72-10 (IGH) Switch pushed Below 1 Ω
G72-4 (HSW) - G72-10 (IGH) Switch not pushed 10 kΩ or higher