| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L182-1 (L) - L182-2 (B) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| Battery positive (+) → L182-1 (-) Battery negative (-) → L182-2 (+) |
- | Operates (operating sound heard) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) → P10-1 (B) Battery negative (-) → P10-2 (E) |
- | Operates (operating sound heard) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L181-1 (SMTI) - L181-2 (E1) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| L181-3 (SMSI) - L181-2 (E1) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| L183-1 (SMOS) - L183-2 (E2) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| L183-3 (SMTO) - L183-2 (E2) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| Battery positive (+) → L181-1 (SMTI) Battery negative (-) → L181-2 (E1) |
- | Operates (operating sound heard) |
| Battery positive (+) → L181-3 (SMSI) Battery negative (-) → L181-2 (E1) |
- | Operates (operating sound heard) |
| Battery positive (+) → L183-1 (SMOS) Battery negative (-) → L183-2 (E2) |
- | Operates (operating sound heard) |
| Battery positive (+) → L183-3 (SMTO) Battery negative (-) → L183-2 (E2) |
- | Operates (operating sound heard) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L3-2 (PACC) - L3-3 (SHB) | Apply 5 V between terminals 1 (SHG) and 3 (SHB). | 0.5 to 4.5 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A42-2 (PAC2) - A42-3 (SHB) | Apply 5 V between terminals 1 (SHG) and 3 (SHB). | 0.5 to 4.5 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L180-1 (SBL) - L180-2 (TOIL) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 15°C (59°F) | 2.45 to 2.88 kΩ | |
| 20°C (68°F) | 1.95 to 2.30 kΩ | |
| 25°C (77°F) | 1.60 to 1.80 kΩ | |
| 30°C (86°F) | 1.28 to 1.47 kΩ | |
| 35°C (95°F) | 1.00 to 1.22 kΩ | |
| 40°C (104°F) | 0.80 to 1.00 kΩ | |
| 45°C (113°F) | 0.65 to 0.85 kΩ | |
| 50°C (122°F) | 0.50 to 0.70 kΩ | |
| 55°C (131°F) | 0.44 to 0.60 kΩ | |
| 60°C (140°F) | 0.36 to 0.50 kΩ |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-1 (RH+) - A38-2 (E) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| A38-3 (LH+) - A38-2 (E) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| Battery positive (+) → A38-1 (RH+) Battery negative (-) → A38-2 (E) |
- | Sound of No. 1 height control valve operating can be heard |
| Battery positive (+) → A38-3 (LH+) Battery negative (-) → A38-2 (E) |
- | Sound of No. 1 height control valve operating can be heard |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| L177-1 (RH+) - L177-2 (E) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| L177-3 (LH+) - L177-2 (E) | at 20°C (68°F) | 9.36 to 10.14 Ω |
| Battery positive (+) → L177-1 (RH+) Battery negative (-) → L177-2 (E) |
- | Sound of No. 2 height control valve operating can be heard |
| Battery positive (+) → L177-3 (LH+) Battery negative (-) → L177-2 (E) |
- | Sound of No. 2 height control valve operating can be heard |
| Tester Connection | Condition | Specified Condition | |
|---|---|---|---|
| for 2WD: for LH Side |
A74-2 (SHFL) - A74-1 (SHG) | +30° (High) | 3.45 V |
| for 2WD: for LH Side |
A74-2 (SHFL) - A74-1 (SHG) | 0° (Standard position) | 2.25 V |
| for 2WD: for LH Side |
A74-2 (SHFL) - A74-1 (SHG) | -30° (Low) | 1.05 V |
| for 2WD: for RH Side |
A75-2 (SHFR) - A75-1 (SHG) | +30° (High) | 3.45 V |
| for 2WD: for RH Side |
A75-2 (SHFR) - A75-1 (SHG) | 0° (Standard position) | 2.25 V |
| for 2WD: for RH Side |
A75-2 (SHFR) - A75-1 (SHG) | -30° (Low) | 1.05 V |
| for AWD: for LH Side |
A68-2 (SHFL) - A68-1 (SHG) | +30° (High) | 3.45 V |
| for AWD: for LH Side |
A68-2 (SHFL) - A68-1 (SHG) | 0° (Standard position) | 2.25 V |
| for AWD: for LH Side |
A68-2 (SHFL) - A68-1 (SHG) | -30° (Low) | 1.05 V |
| for AWD: for RH Side |
A69-2 (SHFR) - A69-1 (SHG) | +30° (High) | 3.45 V |
| for AWD: for RH Side |
A69-2 (SHFR) - A69-1 (SHG) | 0° (Standard position) | 2.25 V |
| for AWD: for RH Side |
A69-2 (SHFR) - A69-1 (SHG) | -30° (Low) | 1.05 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| for LH Side | +45° (High) | 4.1 V |
| for LH Side | 0° (Standard position) | 2.25 V |
| for LH Side | -45° (Low) | 0.45 V |
| for RH Side | +45° (High) | 4.1 V |
| for RH Side | 0° (Standard position) | 2.25 V |
| for RH Side | -45° (Low) | 0.45 V |
| Tester Connection | Condition | Specified Condition | |
|---|---|---|---|
| for LH Side | L47-1 (SGFL) - L47-2 (SGG) | Sensor stationary | Approx. 2.0 to 2.5 V |
| for LH Side | L47-1 (SGFL) - L47-2 (SGG) | Sensor vibrating vertically | Changes between approx. 0.9 and 3.6 V |
| for RH Side | L36-1 (SGFR) - L36-2 (SGG) | Sensor stationary | Approx. 2.0 to 2.5 V |
| for RH Side | L36-1 (SGFR) - L36-2 (SGG) | Sensor vibrating vertically | Changes between approx. 0.9 and 3.6 V |
| Tester Connection | Condition | Specified Condition | |
|---|---|---|---|
| for 2WD: for LH Side |
A14-1 (FAL-) - A14-2 (FAL+) | 15 to 25°C | 2.8 to 4.4 Ω |
| for 2WD: for RH Side |
A23-1 (FAR-) - A23-2 (FAR+) | 15 to 25°C | 2.8 to 4.4 Ω |
| for AWD: for LH Side |
A70-1 (FAL-) - A70-3 (FAL+) | 15 to 25°C | 2.8 to 4.4 Ω |
| for AWD: for RH Side |
A71-1 (FAR-) - A71-3 (FAR+) | 15 to 25°C | 2.8 to 4.4 Ω |
| Tester Connection | Condition | Specified Condition | |
|---|---|---|---|
| for LH side | L75-1 (RAL+) - L75-3 (RAL-) | 15 to 25°C | 2.8 to 4.4 Ω |
| for RH side | z25-1 (RAR+) - z25-3 (RAR-) | 15 to 25°C | 2.8 to 4.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G49-3 (P) - G49-7 (GND) | Combination switch assembly knob turned and held at S/S+ position | Below 50 Ω |
| G49-3 (P) - G49-7 (GND) | Combination switch assembly knob not turned to S/S+ position | 10 kΩ or higher |
| G49-2 (B) - G49-7 (GND) | Normal/Custom mode switch pushed and held | Below 50 Ω |
| G49-2 (B) - G49-7 (GND) | Normal/Custom mode switch not pushed | 10 kΩ or higher |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G72-4 (HSW) - G72-10 (IGH) | Switch pushed | Below 1 Ω |
| G72-4 (HSW) - G72-10 (IGH) | Switch not pushed | 10 kΩ or higher |