AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONER PRESSURE SENSOR


    1. Apply a sufficient amount of compressor oil to a new air conditioner pressure sensor.

      Compressor oil
      ND-OIL 11 or equivalent

      Note


      • Keep the O-ring and O-ring fitting surfaces clean from dirt or any foreign matter.

      • Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

    2. Using a 27 mm deep socket wrench, install the new air conditioner pressure sensor.

      Torque:
      11 N*m  { 110 kgf*cm, 8 ft.*lbf }

      Note


      • Do not deform the piping.

      • Make sure to confirm that the piping does not disengage from the plastic clamp.

    3. Connect the connector.

  2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFC-134a(R134a))

    Click here

  3. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFO-1234yf(R1234yf))

    Click here

  4. WARM UP COMPRESSOR (for HFC-134a(R134a))

    Click here

  5. WARM UP COMPRESSOR (for HFO-1234yf(R1234yf))

    Click here

  6. INSPECT FOR REFRIGERANT LEAK (for HFC-134a(R134a))

    Click here

  7. INSPECT FOR REFRIGERANT LEAK (for HFO-1234yf(R1234yf))

    Click here