AIR CONDITIONING SYSTEM(except Automatic Air Conditioning System) IG Power Source Circuit

DTC Code DTC Name
IG Power Source Circuit

DESCRIPTION

Power source voltage is supplied to the air conditioning control assembly when the ignition switch is ON. This power is used for operating the air conditioning control assembly, servo motors, etc.

WIRING DIAGRAM

E290891E06

CAUTION / NOTICE / HINT

Note:

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE

  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - IG POWER SOURCE)

    1. Disconnect the E26 air conditioning control assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection

      Condition

      Specified Condition

      E26-10 (IG+) - Body ground

      Ignition switch off

      Below 1 V

      Ignition switch ON

      11 to 14 V

    Result

    Proceed to

    OK

    NG

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR

    OK
  2. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND)

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      E26-7 (GND) - Body ground

      Always

      Below 1 Ω

    Result

    Proceed to

    OK

    NG

    OK

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR