AIR CONDITIONING SYSTEM(except Automatic Air Conditioning System) IG Power Source Circuit
| DTC Code | DTC Name |
|---|---|
| IG Power Source Circuit |
DESCRIPTION
Power source voltage is supplied to the air conditioning control assembly when the ignition switch is ON. This power is used for operating the air conditioning control assembly, servo motors, etc.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - IG POWER SOURCE)
Disconnect the E26 air conditioning control assembly connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
E26-10 (IG+) - Body ground
Ignition switch off
Below 1 V
Ignition switch ON
11 to 14 V
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
E26-7 (GND) - Body ground
Always
Below 1 Ω
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR