ТОПЛИВНАЯ СИСТЕМА ДВИГАТЕЛЯ COMMON RAIL ПРОВЕРКА


  1. COMMON RAIL ASSEMBLY


    1. Inspect the fuel pressure sensor


      1. B007SIQE13

        Measure the resistance according to the value(s) in the table below.

        Standard
        Terminals Resistance
        2(PR) - Body Below 3k Ω
        1(E2) - 2(PR) Below 16.4kΩ
    2. Inspect the pressure discharge valve resistance.


      1. B007VL3

        Measure the resistance between the terminals.

        Resistance
        0.85 to 1.05 Ω at 20°C (68°F)