| DTC Code | DTC Name |
|---|---|
| C1AB6 | Blind Spot Monitor Master Module |
DESCRIPTION
This DTC is stored when the blind spot monitor sensor RH detects an internal malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C1AB6 | Blind Spot Monitor Master Module | The blind spot monitor sensor RH (master) detects an internal malfunction | Blind spot monitor sensor RH |
CAUTION / NOTICE / HINT
Note
When checking for DTCs, make sure that the blind spot monitor system is turned on.
PROCEDURE
CHECK DTC
Clear the DTCs.
Turn the engine switch off.
Turn the engine switch on (IG).
Check for DTCs and check if the same DTC is output again.
| OK |
|---|
| DTC C1AB6 is not output. |
| Result | |||
|---|---|---|---|
|
| OK |
|
USE SIMULATION METHOD TO CHECK Click here |
| NG |
|
REPLACE BLIND SPOT MONITOR SENSOR RH Click here |