HAZARD WARNING SWITCH INSPECTION
PROCEDURE
INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
4 (TB) - 1 (E)
Hazard warning signal switch off
10 kΩ or higher
Hazard warning signal switch on
Below 1 Ω
Apply battery voltage to the connector and check the LED illumination condition.
OK
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 3 (ILL+)
Battery negative (-) → Terminal 2 (ILL-)
LED illuminates
Table 1. Text in Illustration *1
Component without harness connected
(Hazard Warning Signal Switch Assembly)
If the result is not as specified, there may be a malfunction in the hazard warning signal switch.
-