HAZARD WARNING SWITCH INSPECTION

PROCEDURE

  1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY

    1. E107908E13

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Switch Condition

      Specified Condition

      4 (TB) - 1 (E)

      Hazard warning signal switch off

      10 kΩ or higher

      Hazard warning signal switch on

      Below 1 Ω

    2. Apply battery voltage to the connector and check the LED illumination condition.

      OK

      Measurement Condition

      Specified Condition

      Battery positive (+) → Terminal 3 (ILL+)

      Battery negative (-) → Terminal 2 (ILL-)

      LED illuminates

      Table 1. Text in Illustration

      *1

      Component without harness connected

      (Hazard Warning Signal Switch Assembly)

      If the result is not as specified, there may be a malfunction in the hazard warning signal switch.