COMBINATION METER REMOVAL

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during combination meter assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Disconnect cable from negative battery terminal Perform steering sensor zero point calibration Lane departure alert system (w/ Steering Control)

Click here

Pre-collision system
Memorize steering angle neutral point Parking assist monitor system

Click here

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

    Click here

  2. CHANGE POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM SETTINGS (for Power Tilt and Power Telescopic Steering Column)

    Click here

  3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    for 2AR-FE:

    Click here

    for A25A-FKS:

    Click here

    for 2GR-FKS:

    Click here

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  4. REMOVE NO. 1 METER HOOD CLUSTER

    Click here

  5. REMOVE NO. 2 METER HOOD CLUSTER

    Click here

  6. REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY


    1. for Manual Tilt and Manual Telescopic Steering Column:


      1. Release the tilt and telescopic lever and fully extend and lower the steering column assembly.

      2. Lock the tilt and telescopic lever.

    2. B0085APC01
      B0087TV Protective Tape

      Apply protective tape to the area shown in the illustration.

    3. B00849SC01
      B0087TV Protective Tape

      Apply protective tape to the area shown in the illustration.

    4. B0084HHC01
      B00847Z Remove in this Direction

      Disengage the 2 claws and 4 clips to separate the instrument cluster finish panel assembly.

    5. B0087YI

      Remove the 2 clips.

    6. B0086Q2C01
      B0089GN Place Hand Here
      B00847Z Remove in this Direction

      Disengage the 2 clips as shown in the illustration.

    7. B0089G8C01
      B0089GN Place Hand Here
      B00847Z Remove in this Direction

      Disengage the 2 clips as shown in the illustration.

    8. B00898UC01
      B00847Z Remove in this Direction

      Disengage the 2 guides as shown in the illustration.

    9. Disconnect the connector to remove the instrument cluster finish panel assembly.

  7. REMOVE COMBINATION METER ASSEMBLY


    1. B0087NK

      Remove the 3 screws.

    2. B0084VAC01
      B00847Z Remove in this Direction

      Disengage the 2 clips as shown in the illustration.

    3. Disengage the clamp.

    4. Disconnect each connector to remove the combination meter assembly.