MAIN BODY ECU(for RHD) INSTALLATION
PROCEDURE
INSTALL MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
Note:Make sure that no foreign matter gets on the connecting surfaces.
Do not touch the ECU connector.
-
*a
20°
*b
Housing Sidewall
Set the main body ECU (multiplex network body ECU) to the position where the guide of the main body ECU (multiplex network body ECU) contacts the housing sidewall of the junction block as shown in the illustration.
Tip:Make sure to keep the angle at 20° or more as shown in the illustration.
-
*a
Housing Sidewall
*b
Junction Block Fuse
Slide the guide of the main body ECU (multiplex network body ECU) along the housing sidewall so that it contacts the junction block fuse as shown in the illustration.
-
*a
Side A
While keeping the main body ECU (multiplex network body ECU) in contact with side A of the junction block (axis of rotation), lower it as shown in the illustration.
-
*1
Junction Block
*2
Main Body ECU (Multiplex Network Body ECU)
*a
Push Area
Press the push area until the claw engages to install the main body ECU (multiplex network body ECU).
Note:Make sure to press only the push area.
Confirm the engagement of the main body ECU (multiplex network body ECU) and junction block by listening for the click sound of the lock engaging.
Tip:If a click sound cannot be heard, visually check the engagement of the lock. The engagement can also be confirmed if the main body ECU (multiplex network body ECU) and junction block are flush.
INSTALL INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY WITH MAIN BODY ECU
-
*a
Bolt
*b
Screw
Install the instrument panel junction block assembly with main body ECU with the 2 screws and bolt.
Bolt
8.0 N*m
82 kgf*cm
71 in.*lbf
Connect the connector and engage the clamp.
Note:Be sure to connect the connector securely.
-
Connect the 4 connectors and raise each lock lever to engage each claw and lock the connector.
Note:Be sure to connect the connectors securely.
Connect the connector.
Note:Be sure to engage the connector securely.
Engage the 3 clamps.
-
INSTALL GLOVE COMPARTMENT DOOR ASSEMBLY
for Hatchback, Wagon:Click hereClick here
for Sedan:Click hereClick here
INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (w/ Instrument Panel Under Cover)
for Hatchback, Wagon:Click hereClick here
for Sedan:Click hereClick here
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.