1ND-TV ENGINE CONTROL SERVICE DATA

Diesel Throttle Body Assembly

Standard Resistance

1 (M-) - 2 (M+)

0.3 to 100 Ω at 20°C (68°F)

Accel Sensor Out No.1

Standard Voltage

Accelerator pedal is released

0.5 to 1.1 V

Accelerator pedal is fully depressed

2.6 to 4.5 V

Accel Sensor Out No.2

Standard Voltage

Accelerator pedal is released

1.2 to 2.0 V

Accelerator pedal is fully depressed

3.4 to 4.75 V

Mass Air Flow Meter Sub-assembly

(w/ Glow Plug Controller)

Standard Condition

MAF

3 to 10 gm/sec at Idling

10 to 25 gm/sec at 2000 rpm

30 to 50 gm/sec at 3000 rpm

Standard Resistance

4 (THA) - 2 (E2G)

13.6 to 18.4 kΩ at -20°C (-4°F)

2.21 to 2.69 kΩ at 20°C (68°F)

0.49 to 0.67 kΩ at 60°C (140°F)

Mass Air Flow Meter Sub-assembly

(w/o Glow Plug Controller)

Standard Resistance

4 (THA) - 5 (E2)

12.5 to 16.9 kΩ at -20°C (-4°F)

2.19 to 2.67 kΩ at 20°C (68°F)

0.50 to 0.68 kΩ at 60°C (140°F)

Camshaft Position Sensor

(w/o Glow Plug Controller)

Standard Resistance

1 - 2

835 to 1400 Ω at Cold

1060 to 1645 Ω at Hot

Crank Position Sensor

Standard Resistance

1 - 2

1630 to 2740 Ω at Cold

2065 to 3225 Ω at Hot

Engine Coolant Temperature Sensor

Standard Resistance

1 - 2

2.32 to 2.59 kΩ at 20°C (68°F)

0.310 to 0.326 kΩ at 80°C (176°F)

Intake Air Temperature Sensor

Standard Resistance

1 (THA) - 2 (E2)

2.21 to 2.65 kΩ at Approximately 20°C (68°F)

0.55 to 0.61 kΩ at Approximately 60°C (140°F)

Diesel Turbo Pressure Sensor

Standard Voltage

B126-3 (VC) - B126-1 (E)

4.75 to 5.25 V at Ignition switch ON

Air Fuel Ratio Sensor

(w/ Glow Plug Controller)

Standard Resistance

5 (HAF1) - 2 (+B)

5 (HAF2) - 2 (+B)

2 to 5 Ω at 20°C (68°F)

5 (HAF1) - 4 (AF1+)

5 (HAF2) - 4 (AF2+)

10 kΩ or higher at Always

Air Fuel Ratio Sensor

(w/o Glow Plug Controller)

Standard Resistance

5 (H-) - 2 (+B)

2 to 5 Ω at 20°C (68°F)

5 (H-) - 4 (AF1+)

10 kΩ or higher at Always

EFI-MAIN Relay

Standard Resistance

3 - 5

10 kΩ or higher

(Battery voltage not applied to terminals 1 and 2)

Below 1 Ω

(Battery voltage applied to terminals 1 and 2)

IG2 Relay

Standard Resistance

3 - 5

10 kΩ or higher

(Battery voltage not applied to terminals 1 and 2)

Below 1 Ω

(Battery voltage applied to terminals 1 and 2)