DESCRIPTION
The cause of the malfunction may be the low-voltage circuit.
Check whether there is an open circuit in the inverter +B low-voltage power source system or a problem in the communication between the hybrid vehicle control ECU assembly and inverter.
| Area | Inspection | Step |
|---|---|---|
| Inverter +B low-voltage power source system check | Check for inverter overcurrent malfunction. | 1, 2 |
| Communication malfunction between hybrid vehicle control ECU assembly and MG-ECU inside inverter with converter assembly | Check for inverter overcurrent malfunction due to communication malfunction. | 3, 4 |
| Check for short to ground in inverter +B low-voltage power source system | - | 5, 6, 7 |
WIRING DIAGRAM
CAUTION / NOTICE / HINT
This step is referenced from the procedures for each DTC.
If the inspection results below are normal, perform the next procedure for the referenced DTC.
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
PROCEDURE
CHECK FUSE (IGCT NO. 2)
| *1 | No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly |
| *2 | IGCT NO. 2 Fuse |
Remove the IGCT NO. 2 fuse from the No. 1 engine room relay block and No. 1 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the IGCT NO. 2 fuse.
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT NO. 2 FUSE) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A83*1 or A26*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A83*1 or A26*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE POWER SOURCE CIRCUIT |
| OK |
|
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU ASSEMBLY - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A83*1 or A26*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Disconnect the A81 hybrid vehicle control ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
*b | Rear view of wire harness connector (to Hybrid Vehicle Control ECU Assembly) |
| Standard Resistance (Check for Open) | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Open) | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Voltage | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the hybrid vehicle control ECU assembly and inverter with converter assembly connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A81 hybrid vehicle control ECU assembly connector.
Reconnect the A83*1 or A26*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HYBRID VEHICLE CONTROL ECU ASSEMBLY
Disconnect the A81 hybrid vehicle control ECU assembly connector.
| *a | Component without harness connected (Hybrid Vehicle Control ECU Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the A81 hybrid vehicle control ECU assembly connector.
| Result | |||
|---|---|---|---|
|
| OK |
|
INVERTER LOW-VOLTAGE CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC) |
| NG |
|
REPLACE HYBRID VEHICLE CONTROL ECU ASSEMBLY Click here |
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT NO. 2 FUSE)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A83*1 or A26*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the A83*1 or A26*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR Click here |
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
| Result | ||
|---|---|---|
|
| NEXT |
|
REPLACE FUSE (IGCT NO. 2) |
REPAIR OR REPLACE HARNESS OR CONNECTOR
| Result | ||
|---|---|---|
|
| NEXT |
|
REPLACE FUSE (IGCT NO. 2) |