TRIP SWITCH INSPECTION

PROCEDURE

  1. INSPECT TRIP SWITCH

    1. E205796C01

      *a

      Component without harness connected

      (Trip Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Switch Condition

      Specified Condition

      10 (A/B) - 11 (E)

      ODO/TRIP switch on (Pushed)

      Below 1 Ω

      ODO/TRIP switch off (Not pushed)

      1 MΩ or higher

      If the result is not as specified, replace the trip switch.

    2. Inspect the switch illumination.

      1. Apply battery voltage between the terminals of the light and check the operation of the light.

        OK

        Measurement Condition

        Specified Condition

        Battery positive (+) → Terminal 9 (ILL+)

        Battery negative (-) → Terminal 12 (ILL-)

        Light comes on

        If the result is not as specified, replace the trip switch.