TRIP SWITCH INSPECTION
PROCEDURE
INSPECT TRIP SWITCH
-
*a
Component without harness connected
(Trip Switch)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
10 (A/B) - 11 (E)
ODO/TRIP switch on (Pushed)
Below 1 Ω
ODO/TRIP switch off (Not pushed)
1 MΩ or higher
If the result is not as specified, replace the trip switch.
Inspect the switch illumination.
Apply battery voltage between the terminals of the light and check the operation of the light.
OK
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 9 (ILL+)
Battery negative (-) → Terminal 12 (ILL-)
Light comes on
If the result is not as specified, replace the trip switch.
-