DESCRIPTION
If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.
| Symptom | Factor |
|---|---|
|
|
PROCEDURE
CHECK AIR CONDITIONING SYSTEM
Operate the blower switch with the following conditions met and check that the airflow volume changes.
| Blower Speed | Condition |
|---|---|
| LO → HI |
|
| OK |
|---|
| Airflow volume increases. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit) Click here |
| OK |
|
CHECK CLEAN AIR FILTER
Visually check the clean air filter.
| OK |
|---|
| The clean air filter is not dirty or clogged. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE CLEAN AIR FILTER Click here |
| OK |
|
CHECK NO. 1 COOLER THERMISTOR
Check the installation condition of the No. 1 cooler thermistor.
| OK |
|---|
| The No. 1 cooler thermistor is installed correctly. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY Click here |
| NG |
|
INSTALL NO. 1 COOLER THERMISTOR CORRECTLY Click here |