AIR CONDITIONING SYSTEM GENERAL GENERAL

  1. OUTLINE

    1. An automatic air conditioning system, manual air conditioning system and heater system are available depending on the model.

  2. SPECIFICATION

    1. Performance

      Heater

      Heater Output

      W

      5300

      Air Flow Volume

      m3/h

      240

      Power Consumption

      W

      220

      Air Conditioner

      Cooling Capacity

      W (Kcal/h)

      5000

      Air Flow Volume

      m3/h

      410

      Power Consumption

      W

      250

    2. Blower Motor Sub-assembly

      Heater Radiator Unit Sub-assembly

      Type

      Counter Flow (Mechanical)

      Size: W x H x L

      mm (in.)

      234 x 118.5 x 27 (9.2 x 4.6 x 1.0)

      Fin Pitch

      mm (in.)

      0.9 (0.04)

      Blower with Fan Motor Sub-assembly

      Type

      Brush Motor

      Fin Size: Dia x H

      mm (in.)

      165 x 70 (6.5 x 2.7)

    3. Air Conditioning

      Cooler Condenser Assembly

      Type

      Sub Cool

      Size: W x H x L

      mm (in.)

      355 x 355 x 16 (14.0 x 14.0 x 0.63)

      Fin Pitch

      mm (in.)

      2.4 (0.09)

      No. 1 Cooler Evaporator Sub-assembly

      Type

      Laminate

      Size: W x H x L

      mm (in.)

      240 x 200 x 48 (9.4 x 7.9 x 1.9)

      Fin Pitch

      mm (in.)

      3.0 (0.12)

      Compressor with Pulley Assembly

      Type

      KC59 (Rotary Vane Type)

  3. MAIN FEATURES

    1. The air conditioning system has the following features:

      Others

      The following parts are used to ensure high cooling performance while realizing a compact and lightweight construction.

      • Semi-center location air conditioning unit

      • Laminate type evaporator

      • Sub-cool condenser assembly