GENERATOR(for 150 A Type) INSTALLATION

PROCEDURE

  1. INSTALL GENERATOR ASSEMBLY

    1. Install the generator assembly with the 2 bolts.

      52 N*m

      530 kgf*cm

      38 ft.*lbf

    2. Install the wire harness clamp bracket with the bolt.

      10 N*m

      102 kgf*cm

      7 ft.*lbf

    3. Connect the generator wire with the nut.

      9.8 N*m

      100 kgf*cm

      87 in.*lbf

    4. Install the terminal cap.

    5. Connect the generator connector.

  2. INSTALL WIRE HARNESS CLAMP BRACKET

    1. Install the wire harness clamp bracket with the bolt.

      10 N*m

      102 kgf*cm

      7 ft.*lbf

    2. Attach the wire harness clamp to the wire harness clamp bracket.

  3. INSTALL FAN AND GENERATOR V BELT

  4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick here