GENERATOR(for 150 A Type) INSTALLATION
PROCEDURE
INSTALL GENERATOR ASSEMBLY
Install the generator assembly with the 2 bolts.
52 N*m
530 kgf*cm
38 ft.*lbf
Install the wire harness clamp bracket with the bolt.
10 N*m
102 kgf*cm
7 ft.*lbf
Connect the generator wire with the nut.
9.8 N*m
100 kgf*cm
87 in.*lbf
Install the terminal cap.
Connect the generator connector.
INSTALL WIRE HARNESS CLAMP BRACKET
Install the wire harness clamp bracket with the bolt.
10 N*m
102 kgf*cm
7 ft.*lbf
Attach the wire harness clamp to the wire harness clamp bracket.
INSTALL FAN AND GENERATOR V BELT
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.