VACUUM PUMP(for 8NR-FTS) INSPECTION
PROCEDURE
INSPECT VACUUM PUMP VANE
-
*1
Vacuum Pump Vane Cap
*2
Vacuum Pump Vane
Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn out.
Tip:If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn out, replace the damaged parts with new ones.
-
*a
10 mm (0.394 in.)
Using a micrometer, measure length (A) of the vacuum pump vane with the vacuum pump vane caps removed.
Minimum Length (A)
23.8 mm (0.937 in.)
Note:Measure the length 10 mm (0.394 in.) in from each end of the vacuum pump vane.
Tip:If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.
-
*1
Vacuum Pump Vane
*2
Vacuum Pump Vane Cap
*a
5 mm (0.197 in.)
Using a vernier caliper, measure length (B) of the vacuum pump vane with the vacuum pump vane caps installed.
Minimum Length (B)
76.0 mm (3.00 in.)
Note:Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps.
Tip:If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones.
-
INSPECT VACUUM PUMP HOUSING
-
Check that the areas shown in the illustration are not damaged or excessively worn out.
Tip:If the areas shown in the illustration are damaged or excessively worn out, replace the vacuum pump assembly.
-