OCCUPANT DETECTION SENSOR INSPECTION

PROCEDURE

  1. INSPECT SEPARATE TYPE FRONT SEAT CUSHION PAD

    B455357
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      1 - 3

      More than 147 N (15 kgf, 33.0 lbf) applied to occupant detection sensor

      Below 100 Ω

      If the result is not as specified, replace the seat cushion pad.