AIR CONDITIONING SYSTEM Blower Motor Circuit

DESCRIPTION

The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM

A005ESYE06
*a from Auxiliary Battery
*b Front Blower Motor with Fan Sub-assembly
*c Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. PERFORM ACTIVE TEST USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
      OK
      Blower motor with fan sub-assembly operates and blower motor speed level changes.
      Result
      Result Proceed to
      OK A
      NG (Blower motor does not operate) B
      NG (Blower motor operates but does not change speed) C

    A
    C
    B
  2. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - BODY GROUND)


    1. Disconnect the L33 blower motor with fan sub-assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L33-1 (GND) - Body ground Always Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - POWER SOURCE)


    1. A0059U4E01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Blower Motor with Fan Sub-assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L33-3 (+B) - Body ground Power switch off 11 to 14 V

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN - AIR CONDITIONING AMPLIFIER)


    1. Disconnect the L17 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      L17-23 (BLW) - L33-2 (SI) Always Below 1 Ω
      L17-23 (BLW) - Body ground Always 10 kΩ or higher

    NG
    OK
  5. INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. Reconnect the L33 blower motor with fan sub-assembly connector.

    2. A005CUNE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L17-23 (BLW) - Body ground Power switch off 4.5 to 5.5 V

    NG
    OK
  6. INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY


    1. A005F3BE02
      Text in Illustration
      *a

      Component with harness connected

      (Air Conditioning Amplifier Assembly)

      Remove the air conditioning amplifier assembly Click here.

    2. Reconnect the L17 air conditioning amplifier assembly connector.

    3. Turn the power switch on (IG).

    4. Set the blower speed to low.

    5. Measure the waveform between terminal L17-23 (BLW) of the air conditioning amplifier assembly and body ground.

      Item Content
      Tool setting 1 V/DIV., 500 μs/DIV.
      Vehicle condition

      Power switch on (IG)

      Blower set to low

      OK
      Waveform is as shown in the illustration.

      Tech Tips

      The waveform varies with the blower speed.


    OK
    NG