WASTE GATE VALVE ACTUATOR INSTALLATION

PROCEDURE


  1. INSTALL WASTE GATE VALVE ACTUATOR WITH BRACKET ASSEMBLY

    Note

    After removal and installation of the waste gate valve actuator with bracket assembly, make sure to check the travel of the waste gate valve actuator.

    Click here


    1. Install the waste gate valve actuator with bracket assembly with the 2 bolts.

      Torque:
      24 N*m  { 245 kgf*cm, 18 ft.*lbf }

      Tech Tips

      If more than 1 adjustment washer is installed between the waste gate valve actuator with bracket assembly and compressor housing with bearing sub-assembly, install the washers to their original locations.

    2. Install a new E-washer to the waste gate valve actuator with bracket assembly link pin.

      Note

      Do not reuse the E-washer.

    3. Connect the vacuum transmitting hose assembly to the waste gate valve actuator with bracket assembly.

      Note

      Make sure that the vacuum transmitting hose assembly is installed all the way to the bent portion of the pipe of the waste gate valve actuator.

  2. INSPECT WASTE GATE VALVE ACTUATOR WITH BRACKET ASSEMBLY

    Click here

  3. INSTALL NO. 1 EXHAUST MANIFOLD HEAT INSULATOR

    Click here

  4. CONNECT INTAKE AIR RESONATOR

    Click here

  5. INSTALL OUTLET COMPRESSOR ELBOW

    Click here

  6. INSTALL NO. 5 EXHAUST MANIFOLD HEAT INSULATOR

    Click here

  7. INSTALL NO. 2 AIR CLEANER HOSE

    Click here

  8. INSTALL INTAKE AIR CONNECTOR

    Click here

  9. INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

    Click here

  10. INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY

    Click here