PROCEDURE
INSTALL WASTE GATE VALVE ACTUATOR WITH BRACKET ASSEMBLY
Note
After removal and installation of the waste gate valve actuator with bracket assembly, make sure to check the travel of the waste gate valve actuator.
Install the waste gate valve actuator with bracket assembly with the 2 bolts.
Tech Tips
If more than 1 adjustment washer is installed between the waste gate valve actuator with bracket assembly and compressor housing with bearing sub-assembly, install the washers to their original locations.
Install a new E-washer to the waste gate valve actuator with bracket assembly link pin.
Note
Do not reuse the E-washer.
Connect the vacuum transmitting hose assembly to the waste gate valve actuator with bracket assembly.
Note
Make sure that the vacuum transmitting hose assembly is installed all the way to the bent portion of the pipe of the waste gate valve actuator.
INSPECT WASTE GATE VALVE ACTUATOR WITH BRACKET ASSEMBLY
INSTALL NO. 1 EXHAUST MANIFOLD HEAT INSULATOR
CONNECT INTAKE AIR RESONATOR
INSTALL OUTLET COMPRESSOR ELBOW
INSTALL NO. 5 EXHAUST MANIFOLD HEAT INSULATOR
INSTALL NO. 2 AIR CLEANER HOSE
INSTALL INTAKE AIR CONNECTOR
INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE