KNOCK SENSOR INSTALLATION
CAUTION / NOTICE / HINT
Tip:
Perform "Inspection After Repairs" after replacing the knock sensor.
for K111, K111F:
except K111, K111F:
PROCEDURE
INSTALL KNOCK SENSOR
-
*a
Top
Install the knock sensor with the bolt.
21 N*m
214 kgf*cm
15 ft.*lbf
Note:Make sure that the knock sensor is in the correct position.
Tip:Perform "Inspection After Repairs" after replacing the knock sensor.
for K111, K111F:
except K111, K111F:
Connect the knock sensor connector.
-
INSTALL INTAKE MANIFOLD