2AR-FXE BATTERY / CHARGING SERVICE DATA
Auxiliary battery voltage |
Positive (+) terminal - Negative (-) terminal |
20°C (68°F), Power switch off |
12.5 V or higher Auxiliary battery is OK |
11.0 to 12.5 V Recharge auxiliary battery |
|||
Below 11.0 V Replace auxiliary battery |
|||
Recharge auxiliary battery |
S55D23R |
5.0 A |
|
S46B24R |
4.2 A |
||
Fuse |
Standard resistance |
Below 1 Ω |
|
DC/DC converter assembly |
Current flowing from auxiliary battery Auxiliary battery positive cable |
Power switch on (READY) (The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.) |
0 A or less (no current from auxiliary battery) |
Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal |
13.8 to 14.7 V |
||