COMPRESSOR(for 1PP) INSTALLATION

PROCEDURE

  1. ADJUST COMPRESSOR OIL

    1. When replacing the compressor assembly with pulley with a new one, gradually discharge the inert gas (helium) from the service valve, and drain the following amount of oil before installation.

      Note:
      • If a new compressor assembly with pulley is installed without removing the same amount of compressor oil as is remaining in the pipes, the amount of compressor oil will be excessive. This prevents heat exchange in the refrigerant cycle and will cause the air conditioning system to malfunction.

      • A certain amount of compressor oil remains in the compressor assembly with pulley during circulation and the compressor may be damaged if the amount of compressor oil is more/less than this amount. Therefore, make sure to adjust the amount of compressor oil correctly.

      • If the amount of compressor oil remaining in the removed compressor assembly with pulley is excessively low, check for compressor oil leaks.

      • Do not race the engine before replacing the compressor assembly with pulley.

      • Make sure to use VC200YF or equivalent compressor oil.

    2. E295423C01

      *a

      Drain Bolt (Seal Washer)

      Remove the drain bolt (seal washer) from the removed compressor assembly with pulley.

    3. Drain the compressor oil from the oil port of the removed compressor assembly with pulley as shown in the illustration.

      Note:

      Make sure to drain the compressor oil from the oil port.

      E295461C01

      *a

      Oil Port

      *b

      Turn Clockwise

    4. E295423C01

      *a

      Drain Bolt (Seal Washer)

      Remove the drain bolt (seal washer) from the new compressor assembly with pulley.

      Tip:

      The drain bolt (seal washer) can be reused.

    5. Drain the following amount of compressor oil from the oil port of the new compressor assembly with pulley as shown in the illustration.

      Standard

      (The amount of oil in a new compressor assembly with pulley: 80 cc (2.71 fl.oz)) - (The amount of oil in the removed compressor assembly with pulley) = The amount of oil to be removed from the new compressor assembly with pulley.

      Note:
      • Make sure to drain the compressor oil from the oil port.

      • Make sure to add the compressor oil from the oil port, not from the discharge or intake port.

      • If a tool is used to add compressor oil to the new compressor assembly with pulley, make sure that it is free of foreign matter.

      • If the amount of compressor oil remaining in the removed compressor assembly with pulley cannot be estimated because the compressor was damaged and oil was discharged due to a frontal collision, etc., install the new compressor assembly with pulley without removing any oil. If the cooler condenser assembly is also replaced, do not add the specified amount of compressor oil for cooler condenser assembly replacement (20 cc (0.68 fl.oz)).

      E295461C01

      *a

      Oil Port

      *b

      Turn Clockwise

    6. Install the drain bolt (seal washer) to the new compressor assembly with pulley.

      25 N*m

      255 kgf*cm

      18 ft.*lbf

      Note:

      Make sure that there is no damage or foreign matter on the seal washer edge.

  2. INSTALL COMPRESSOR ASSEMBLY WITH PULLEY

    1. E295159C01
      V100135

      Bolt

      V100136

      Connector

      Temporarily install the compressor assembly with pulley with the 3 bolts.

    2. Tighten the 3 bolts in the order shown in the illustration to install the compressor assembly with pulley.

      24.5 N*m

      250 kgf*cm

      18 ft.*lbf

    3. Connect the connector.

  3. CONNECT DISCHARGE HOSE SUB-ASSEMBLY

    1. Remove the vinyl tape from the discharge hose sub-assembly.

    2. Sufficiently apply compressor oil to 2 new O-rings and the fitting surface of the discharge hose sub-assembly.

      Compressor Oil

      VC200YF or equivalent

    3. Install the 2 O-rings to the discharge hose sub-assembly.

    4. Install the discharge hose sub-assembly to the compressor assembly with pulley with the bolt.

      9.8 N*m

      100 kgf*cm

      87 in.*lbf

  4. CONNECT SUCTION HOSE SUB-ASSEMBLY

    1. Remove the vinyl tape from the suction hose sub-assembly.

    2. Sufficiently apply compressor oil to 2 new O-rings and the fitting surface of the suction hose sub-assembly.

      Compressor Oil

      VC200YF or equivalent

    3. Install the 2 O-rings to the suction hose sub-assembly.

    4. Install the suction hose sub-assembly to the compressor assembly with pulley with the bolt.

      9.8 N*m

      100 kgf*cm

      87 in.*lbf

  5. INSTALL V-RIBBED BELT

  6. INSTALL FRONT UPPER BUMPER SUPPORT

  7. INSTALL FRONT BUMPER COVER

  8. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

  9. WARM UP ENGINE

  10. INSPECT FOR REFRIGERANT LEAK