RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT HORN RELAY ASSEMBLY


    1. A01HK1YN02

      Remove the horn relay assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the horn relay assembly.