HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A02-719 and P0A03-720
| DTC Code | DTC Name |
|---|---|
| P0A02-719 | Motor Electronics Coolant Temperature Sensor Circuit Low |
| P0A03-720 | Motor Electronics Coolant Temperature Sensor Circuit High |
DESCRIPTION
Refer to the description for DTC P0A01-726.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
MIL |
Warning Indicate |
|---|---|---|---|---|---|
P0A02-719 |
Motor Electronics Coolant Temperature Sensor Circuit Low |
Short to ground in the HV coolant temperature sensor circuit (1 trip detection logic) |
Inverter with converter assembly |
Comes on |
Master Warning Light: Comes on |
P0A03-720 |
Motor Electronics Coolant Temperature Sensor Circuit High |
Open or short to +B in the HV coolant temperature sensor circuit (1 trip detection logic) |
Inverter with converter assembly |
Comes on |
Master Warning Light: Comes on |
DTC No. |
Data List |
|---|---|
P0A02-719 |
Inverter Coolant Water Temperature |
P0A03-720 |
CAUTION / NOTICE / HINT
After the repair, clear the DTCs. If "Inverter Coolant Water Temperature" does not show an abnormal value (110°C (230°F) or -50°C (-58°F)) when the power switch is turned on (IG), the condition is judged as normal.
(If a Low malfunction exists in the HV coolant temperature sensor wiring, 110°C (230°F) is displayed and if a High malfunction exists, -50°C (-58°F) is displayed.)
PROCEDURE
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Result
Proceed to
NEXT
NEXT COMPLETED