AUTOMATIC LIGHT CONTROL SENSOR ON-VEHICLE INSPECTION
PROCEDURE
INSPECT AUTOMATIC LIGHT CONTROL SENSOR
-
*a
Component with harness connected
(Automatic Light Control Sensor)
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Switch Condition
Specified Condition
6 (CLTB) - 3 (CLTE)
Ignition switch on (IG)
11 to 14 V
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
3 (CLTE) - Body ground
Always
Below 1 Ω
Reconnect the automatic light control sensor connector.
-
Check the waveform of the automatic light control sensor connector.
Waveform
Tester Connection
Tool Setting
Switch Condition
Specified Condition
3 (CLTE) - 5 (CLTS)
5 V/DIV., 5 msec./DIV.
Ignition switch on (IG), headlight dimmer switch on AUTO
Correct waveform is as shown
Tip:If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, there may be a malfunction in the automatic light control sensor.
-